2. Power up the device.
3. Connect the cables to the new CP blades.
4. Enter
chassisDisable
.
5. Enter
configDownload -vf
to download device virtual fabric data to the local system.
The device reboots and partitions are restored.
6. Enter
chassisDisable
.
7. Enter
configDownload -map
to download port-to-area addressing mode configuration files to the local system.
8. Power-cycle the chassis.
The system recovers.
9. Enter
chassisDisable
.
10. Enter
configDownload -all
to download system configuration data, including chassis and switch configuration for
all logical switches, to the local system.
All the licenses, configurations, and FCIP tunnels are restored.
11. Enter
reboot
.
The device becomes fully functional with the new CP blades.
12. Verify that each blade's power LED is green. If they are not green, ensure that the CP blade has power and is firmly
seated and that the ejectors are in the locked position.
Completing the Replacement
Complete the following steps to complete the CP blade replacement procedure.
1. Enter
haEnable
to re-enable HA on the active CP blade.
NOTE
The
haEnable
command will cause the standby CP blade to reboot. Wait until POST completes—when the
status LED on the CP blade returns to a steady green state—before moving to the next step.
2. Enter
haShow
and verify that the command output includes "HA Enabled, Heartbeat Up". If the output does not include
this phrase, re-enter the command until you have verified that redundancy is achieved.
NOTE
The
haEnable
command will cause the standby CP blade to reboot.
Chassis_1:admin> hashow
Local CP (Slot 2, CP1) : Active
Remote CP (Slot 1, CP0) : Standby, Healthy
HA Enabled, Heartbeat Up, HA State Synchronized
3. Enter
firmwareShow
to verify that the firmware version has been updated and that the versions are the same on the
two CP blades.
If you have one or more port or extension blades in the device, the Fabric OS automatically detects mismatches
between the active CP firmware and the blade's firmware and triggers the auto-leveling process. This auto-leveling
process automatically updates the application blade firmware to match the active CP blade. At the end of the auto-
leveling process, the active CP and extension blades will run the same version of the firmware.