Broadcast Tools SS 4.1 III Installation And Operation Manual Download Page 1

Installation and Operation Manual

Due to the dynamic nature of product design, the information contained in this 
document is subject to change without notice. Broadcast Tools, Inc., assumes no
responsibility for errors and/or omissions contained in this document. Revisions 
of this information or new editions may be issued to incorporate such changes.

Broadcast Tools® is a registered trademark of Broadcast Tools, Inc.

Copyright„ 1989 - 2007 by Broadcast Tools, Inc. All rights reserved.

No part of this document may be reproduced or distributed without permission.

Visit 

www.broadcasttools.com

for important product update information.

Manual Update: 02/13/07

SS 4.1 III

Four Input, Single Output Stereo Switcher/Router

INC

®

Summary of Contents for SS 4.1 III

Page 1: ...ment Revisions of this information or new editions may be issued to incorporate such changes Broadcast Tools is a registered trademarkof Broadcast Tools Inc Copyright 1989 2007 by Broadcast Tools Inc...

Page 2: ...4x1 III Installation and Operation Manual Table of Contents Section Title Page Introduction 3 Safety Information 3 Who to Contact for Help 3 Product Description 4 Applications 4 Front Panel Descriptio...

Page 3: ...and or installation could result in a hazardous condition WHO TO CONTACT FOR HELP If you have any questions regarding your product or you need assistance please con tact your distributor from whom you...

Page 4: ...user to turn off the audio output when activated A Step Input provides a means of stepping though each source including MOH Station Selection A Serial Port allows communication and operation from a c...

Page 5: ...ng con nectors Channel and polarity designators can be found on the chassis as viewed from the rear Remote Control Connector Pluggable Screw terminals Euro and mating connectors are provided for conne...

Page 6: ...io and remote control mating connectors STEP 2 SOURCE TERMINATION RESISTOR REMOVAL Input sources that are not selected are terminated with a 10K W If you do not want this load applied across the desel...

Page 7: ...an nels push button until all LED s flash Factory power up default is source 1 STEP 4 MOUNTING Mount the unit in a rack or desktop allowing adequate airflow for cooling STEP 5 CONNECT YOUR EQUIPMENT T...

Page 8: ...N 1 Commands The start of string character may be either a asterisk or _ underscore character The second character of the string is the unit u number 0 to 3 The third character is the input i number...

Page 9: ...collectors The open collectors may be used to provide status to a remote control point to indicate which source is selected The status output for the select ed output will go low providing a return fo...

Page 10: ...ory Operation Control Front Panel Momentary switches Remote Momentary closure to ground or 5 Volt TTL CMOS Logic levels Serial RS 232c 6P4C reversed modular cable with 9 pin S9 D Sub adapter 2400 9600...

Page 11: ...T TI IE ES S O OR R R RE EM ME ED DI IE ES S TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT...