Broadata Communications LB-KP8 User Manual Download Page 1

4- AND 8-BUTTON KEYPAD 

WITH RS-232 INTERFACE

BCI reserves the right to make changes to the products described herein without

prior notice or consent. No liability is assumed as a result of their use or application.

All rights reserved.

©2019 Broadata Communications, Inc.

LB-KP4  /  LB-KP8

USER MANUAL

Summary of Contents for LB-KP8

Page 1: ...CI reserves the right to make changes to the products described herein without prior notice or consent No liability is assumed as a result of their use or application All rights reserved 2019 Broadata...

Page 2: ...SERVE THE FOLLOWING SAFETY PRECAUTIONS SURGE PROTECTION DEVICE RECOMMENDED This product contains sensitive electrical components that may be damaged by electrical spikes surges electric shock lightnin...

Page 3: ...your dealer In case liquid spillage on device unplug mains power cord and contact your dealer Continu ous use in this case may result in fire or electric shock To reduce the risk of electric shock do...

Page 4: ...ONTENTS PRODUCT DESCRIPTION OPERATION CONTROL AND FUNCTIONS FRONT REAR PANEL CONNECTOR PIN OUT ASSIGNMENT CONFIGURATION SPECIFICATIONS SERVICE PROCEDURE REPLACEMENT POLICY RETURN AND REPAIR SERVICE LI...

Page 5: ...tions configured in the LBC H O R ICP When used in conjunction with the HDBaseT Receiver LBC H O R ICP the keypad provides a convenient way to control all your connected devices Features include 8 key...

Page 6: ...a single gang electrical box or mud ring LIGHT SENSOR Sense the amount of ambient light PROGRAMMABLE BUTTONS Customizable keypad buttons to execute single function or scenes THREADED HOLES FOR WALLPLA...

Page 7: ...mud ring BUTTON LABELS The LB KP8 includes a set of labels for attaching to the face of each button The label sheets include a wide variety of function names that are appropriate for most common appli...

Page 8: ...LB KP8 connects to the LBC H O R IP using a Cat 5 cable that has an RJ 45 termination on one end and a terminal plug termination on the other end Terminate both ends of the CATx cable per the cable di...

Page 9: ...KP8 Connect the transmitter unit to the LBC H O R ICP see LBC H O R ICP user manual for transmitter installation details Apply power to the LBC H O R ICP The LB KP8 will power up and the buttons shou...

Page 10: ...lick on Configure and then click on System The Configure System page will be shown In the System panel make sure that the Keypad Type selected is 8 button keypad On the top menu bar click on Keypad Th...

Page 11: ...with RS 232 Interface User Manual LB KP4 LB KP8 11 CONFIGURATION BUTTON CONFIGURATION On the top menu bar click on Customize and then click on 8 16 Button Keypad The following Button Keypad Definitio...

Page 12: ...e a native control type such as Relay Video Control or Audio Control or an external control type such as RS 232 IR or Telnet Standard button configuration example The following configuration sets butt...

Page 13: ...1 1 In the Edit Button drop down menu select F2 2 Type in Relay 1 Off in the Label field 3 In the Mode drop down menu select Standard 4 In the Action Number drop down menu select Action 1 5 In Spacing...

Page 14: ...he buttons click on Keypad on the top menu bar The following keypad should be shown Click on the Relay 1 On button to turn on Relay 1 Click on the Relay 1 Off button to turn off Relay 1 On the LB KP8...

Page 15: ...he Release state turns off Relay 2 1 In the Edit Button drop down menu select F3 2 In the Label field type in Relay 2 3 In the Mode drop down menu select Toggle 4 In the Action Upon drop down menu sel...

Page 16: ...elect Release 11 In the Action Number drop down menu select Action 1 12 In Spacing field enter 0 0 13 In the Action Type drop down menu select Relay 14 In the Action drop down menu select Relay 2 Off...

Page 17: ...release state Standard button configuration example RS 232 action The following configuration sets button F4 to transmit an RS 232 serial string This configuration requires 2 steps 1 Configure the cu...

Page 18: ...6 Button keypad 1 In the Edit Button drop down menu select F4 2 Type in RS 232 String in the Label field 3 In the Mode drop down menu select Standard 4 In the Action Number drop down menu select Actio...

Page 19: ...32 String button to transmit the string serial string on RS 232 channel 1 On the LB KP8 pressing the F4 button should also transmit the string serial string on RS 232 channel 1 LB KP4 Configuration Th...

Page 20: ...4 07 x1 5 16 Button Operating Temperature 0 C to 40 C Storage Temperature 20 C to 60 C Power Supply 12V 0 5A CERTIFICATIONS CE FCC GREEN COMPLIANCE RoHS ORDER INFORMATION LB KP8 8 Button Keypad with R...

Page 21: ...r serviceable components If you have a problem with your unit please contact the Customer Service Department To facilitate our return repair processing please contact Broadata Communications Inc to ob...

Page 22: ...ions or failure resulting from misuse abuse neglect alterations electrical power problems usage not in accordance with product instructions improper installation or damage determined by BCI to have be...

Page 23: ...a Communications Inc 2545 West 237th Street Suite K Torrance CA 90505 1 800 214 0222 310 530 1416 310 530 5958 Facsimile e mail Sales Broadatacom com Website www broadatacom com 2545 West 237th Street...