Broadata Communications LB-ICP User Manual Download Page 1

LB-ICP

L

INK

 B

RIDGE

TM

I

NLINE

 C

ONTROL

 P

ROCESSOR

LB-KP8

K

EYPAD

, 8 K

EYS

 

WITH

 RS-232 I

NTERFACE

BCI reserves the right to make changes to the products described herein without prior

notice or consent. No liability is assumed as a result of their use or application.  All

rights reserved.

©2013 Broadata Communications, Inc.

Summary of Contents for LB-ICP

Page 1: ...YPAD 8 KEYS WITH RS 232 INTERFACE BCI reserves the right to make changes to the products described herein without prior notice or consent No liability is assumed as a result of their use or applicatio...

Page 2: ...optic connector or an unconnected fiber end unless one can be certain that no exposure to laser energy could occur CAUTION Only service personnel are intended to access the interior of the units It s...

Page 3: ...0 PRODUCT DESCRIPTION 5 2 0 OPERATION CONTROL AND FUNCTIONS 6 2 1 LB ICP FRONT AND REAR PANELS 6 2 2 LB KP8 FRONT AND REAR PANEL 7 3 0 CONNECTOR PINOUT ASSIGNMENT 8 3 1 LB ICP 8 3 2 LB KP8 9 4 0 LB IC...

Page 4: ...net Control and monitor AV devices using a standard Ethernet network or a keypad Front panel port status indicators User friendly customizable control configurations via built in web server LB KP8 8 k...

Page 5: ...Ds Light when the corresponding ports are active high 3 RS 232 Serial port to control devices 4 RS 232 LEDs Light when the corresponding RS 232 ports are active 5 REM LED Light when the unit is set as...

Page 6: ...IR learning 14 IR Learner LED Lighted when the unit is IR learning mode 15 CONFIG Configuration keypad port 16 LAN Ethernet connector 17 RESET Press the button to reset the device back to factory defa...

Page 7: ...ormally Open Relay 1 Common Relay 1 Normally Closed Reserved Do Not Connect Reserved Do Not Connect Digital I O LEDs 1 I O Ch 1 2 I O Ch 2 Remote LED On Remote IR TX LED On IR TX Act On High Level Res...

Page 8: ...set button push to reset to default settings RJ 45 1 TX 2 TX 3 RX 4 N C 5 N C 6 RX 7 N C 8 N C CONFIG Keypad 1 12V keypad power 2 RS 232 IN 3 RS 232 OUT 4 GND IR Learn LED ON in IR Learn mode DIP SW P...

Page 9: ...t 800 214 0222 10 The cable connection between LB KP8 and LB ICP is shown below IR Learner CONFIG LAN RESET 1 IR Out 1 12VDC SW ON Standard RJ45 Termination T 568B 2 White Orange RS232 In 3 Orange RS2...

Page 10: ...arner A standard web browser can be used to access the web pages Accessing Web Server The IP address of the ICP must be obtained in order to access the Web Server There are 2 ways to obtain the IP add...

Page 11: ...menu bar click Configure and then click System This brings up the ICP Login page In the ICP Login type in admin for the Userid and admin for the Password and then click Sign in button The Configure S...

Page 12: ...unit are also configured on this page On the top menu bar click Configure and then click System Auto Mode Select Enable to enable the auto mode triggers defined in the Configure Auto Action page Selec...

Page 13: ...t is set to Open Collector setting the Digital Output State to 1 High will emulate a switch closure to ground Setting the Digital Output State to 0 Low will emulate a switch being open The Open Collec...

Page 14: ...to 5 different actions On the top menu click Configure and then click Key Action Function Key Select the function key F1 through F8 to be defined Function Key Label Type in a label name for the select...

Page 15: ...ion number to be defined Action 1 through Action 5 can be defined Spacing Enter the delay in seconds desired following the command action Action Type Select the action type Available types are None Re...

Page 16: ...Technical Support Sales Broadatacom com 17 Digital Output Options Digital Output Channel Select the digital output channel 1 or 2 Note this option is not available if both Digital IO channels are set...

Page 17: ...channel Channel 3 defaults as a control channel Set Remote Connection Configure System page to Disable in order to configure Channel 3 as a pass through channel Channel 4 Internal serial control chan...

Page 18: ...data Technical Support Sales Broadatacom com 19 Flow Control Select On to enable flow control and Off to disable flow control Flow control is available only on Channel 1 If flow control is enabled Cha...

Page 19: ...al IOs are configured as outputs in the Configure System page All three triggers work independently and can be triggered simultaneously On the top menu click Configure and then click Auto Actions The...

Page 20: ...eiver port within 30 seconds If a valid IR code is not presented within 30 seconds the IR learn process will timeout and the process will need to be re initiated After an IR code is learned successful...

Page 21: ...button next to Key Action Definitions to display the Key Action settings details Click the Details button next to Auto Action Definitions to display Auto Action settings details Click the Details butt...

Page 22: ...User s Manual Link BridgeTM Inline Control Processor Keypad w RS 232 Interface Broadata Technical Support Sales Broadatacom com 23 Click the Key Action Definitions Details button and the following wi...

Page 23: ...Control Processor Keypad w RS 232 Interface Broadata Technical Support 800 214 0222 24 Click the Auto Action Definitions Details button and the following will be displayed Click the IR Code Definition...

Page 24: ...nical Support Sales Broadatacom com 25 Examples Example 1 This example configures the F1 key on the virtual keypad as a toggle key to turn on off Relay channel 1 On the top menu click Configure and th...

Page 25: ...l Processor Keypad w RS 232 Interface Broadata Technical Support 800 214 0222 26 Configure F1 Key toggle release action to turn Relay channel 1 Off as follows Click Submit Changes On the top menu clic...

Page 26: ...l Channel Capacity 2 no flow control or 1 with RTS CTS flow control Baud Rate 2400 to 115200 baud 9600 baud default 8 data bits 1 stop bit no parity Connector Terminal block Digital I O Control Channe...

Page 27: ...s capture distance from panel Relay Control Channel Capacity 2 normally open normally closed relays Relay Contact Rating 24 VDC 1A Connector Terminal block Physical LB ICP Dimensions 4 17 W x 4 10 D x...

Page 28: ...ridge LB ICP LB KP8 System contains no user serviceable components If you have a problem with your unit please contact the Customer Service Department To facilitate our return repair processing please...

Page 29: ...do not include malfunctions or failure resulting from misuse abuse neglect alterations electrical power problems usage not in accordance with product instructions improper installation or damage dete...

Page 30: ...LB LB ICP LB KP8 User s Manual Link BridgeTM Inline Control Processor Keypad w RS 232 Interface Broadata Technical Support Sales Broadatacom com 31...

Page 31: ...LB LB ICP LB KP8 User s Manual Link BridgeTM Inline Control Processor Keypad w RS 232 Interface Broadata Technical Support 800 214 0222 32...

Page 32: ...LB LB ICP LB KP8 User s Manual Link BridgeTM Inline Control Processor Keypad w RS 232 Interface Broadata Technical Support Sales Broadatacom com 33...

Page 33: ...a Communications Inc 2545 West 237th Street Suite K Torrance CA 90505 1 800 214 0222 310 530 1416 310 530 5958 Facsimile e mail CustomerService Broadatacom com Website www broadatacom com 60000 LB ICP...