BroadAccess LOSONE SELECT L400K Instructions Manual Download Page 1

Page 1

MODELS  L400K • L500K  

LOSONE SELECT

®

VENTILATORS

Ceiling/Wall Mount   120V

READ AND SAVE THESE INSTRUCTIONS

Page 1

Installer: Leave this manual with 
the homeowner.
Homeowner: Use and Care 
information on page 3.

!

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 
TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. If 

you have questions, contact the manufacturer at the address or 

telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service panel 

and lock the service disconnecting means to prevent power from 

being switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by a quali

fi

 ed 

person(s) in accordance with all applicable codes and standards, 

including 

fi

 re-rated construction codes and standards.

4. Suf

fi

 cient air is needed for proper combustion and exhausting of 

gases through the 

fl

 ue (chimney) of fuel burning equipment to 

prevent backdrafting. Follow the heating equipment manufacturer’s 

guideline and safety standards such as those published by the 

National Fire Protection Association (NFPA), and the American 

Society for Heating, Refrigeration and Air Conditioning Engineers 

(ASHRAE), and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  To reduce the risk of 

fi

 re, use only metal ductwork.

8.  If this unit is to be installed over a tub or shower, it must be marked 

as appropriate for the application and be connected to a GFCI 

(Ground Fault Interrupter) - protected branch circuit.

9. Never place a switch where it can be reached from a tub or 

shower.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1.  Never leave surface units unattended at high settings. Boilovers 

cause smoking and greasy spillovers that may ignite. Heat oils 

slowly on low or medium settings.

2.  Always turn hood ON when cooking at high heat or when cooking 

fl

 aming foods.

3.  Clean ventilating fans frequently. Grease should not be allowed to 

accumulate on fan or 

fi

 lter.

4.  Use proper pan size. Always use cookware appropriate for the size 

of the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF 
A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*

1.  SMOTHER FLAMES with a close-

fi

 tting lid, cookie sheet, or metal 

tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. 

If the 

fl

 ames do not go out immediately, EVACUATE AND CALL 

THE FIRE DEPARTMENT.

2.  NEVER PICK UP A FLAMING PAN - You may be burned.
3.  DO NOT USE WATER, including wet dishcloths or towels - a violent 

steam explosion will result.

4.  Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already 

know how to operate it.

B. The 

fi

 re is small and contained in the area where it started.

C. The 

fi

 re department is being called.

D. You can 

fi

 ght the 

fi

 re with your back to an exit.

*Based on “Kitchen Firesafety Tips” published by NFPA.

CAUTION

1.  For general ventilating use only. Do not use to exhaust hazard-

ous or explosive materials and vapors.

2. To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 

unit.

3.  Please read speci

fi

 cation label on product for further information 

and requirements.

TABLE OF CONTENTS

This manual is divided into sections as follows:

   “TYPICAL INSTALLATION”

  This section shows a common installation in new and existing, 

frame construction.

  - Mounting (new construction)

  - Mounting (existing construction)

 - 

Wiring

  - Ducting (horizontal blower discharge)

   “MOUNTING OPTIONS”

   “WIRING OPTIONS”

  -Wiring Plate Position

   “DUCTING OPTIONS”

  - Blower Discharge Positions

  - Ducting (vertical blower discharge)

   “USE AND CARE”

   “SERVICE PARTS”

   “WARRANTY”

Summary of Contents for LOSONE SELECT L400K

Page 1: ...ached from a tub or shower TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE 1 Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings 2 Always turn hood ON when cooking at high heat or when cooking flaming foods 3 Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or...

Page 2: ... WIRING PLATE 10 ROUND DUCT GRILLE SCREW FINSHED CEILING MATERIAL GRILLE CEILING JOIST 24 centers shown 2 X 4 FRAMING wide side down MOUNTING BRACKETS Attached to opposite sides of housing up side down so housing is flush with finished ceiling DUCTING Horizontal blower discharge Two ways to connect ductwork to a factory shipped unit Ventilator can be wired from outside of housing Use UL approved c...

Page 3: ... position BLOWER BLOWER Change blower duct connector positions for vertical discharge DUCTING Vertical blower discharge Typical ductwork connection to a ventilator converted to vertical discharge ROOF CAP 10 ROUND DUCT WARNING To reduce the risk of electric shock disconnect from power supply before servicing To clean grille Use appropriate vacuum attachment or remove grille and clean with a soft c...

Page 4: ...uct or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence accident improper maintenance or repair other than by Broan NuTone faulty installation or installation contrary to recommende...

Page 5: ... pueden provocar humo y derrames grasosos que se pueden incendiar Caliente lentamente el aceite en un ajuste bajo o medio 2 Siempre ENCIENDA la campana cuando cocine con alta temperatura o cuando cocine alimentos que se puedan incendiar 3 Limpie con frecuencia los ventiladores No debe permitir que la grasa se acumule en el ventilador ni en el filtro 4 Utilice un sartén de tamaño adecuado Siempre u...

Page 6: ...o y hacia abajo para que el alojamiento quede a nivel del cielo raso terminado COLOCACIÓN DE CONDUCTOS descarga horizontal del ventilador Dos formas de conectar los conductos a una unidad enviada de fábrica El ventilador se puede conectar desde el exterior del alojamiento Use conectores aprobados por UL en la conexión en cumplimien to con los códigos locales VENTILACIÓN EN EL ALERO CODO REDONDO DE...

Page 7: ...ucto para una descarga vertical enviada de fábrica Conector del ventilador y del conducto en posición de descarga vertical VENTILADOR Cambie la posición del conector del ventilador y del conducto para una des carga vertical COLOCACIÓN DE DUCTOS Descarga vertical del ventilador Conexión típica de los conductos al ventilador cambiado a des carga vertical TAPA DEL TECHO CONDUCTO REDONDO DE 10 25 4 cm...

Page 8: ...rían de estado a estado Esta garantía reemplaza todas las garantías anteriores Para calificar para servicio bajo esta garantía usted debe a notificar a Broan NuTone en la dirección o el número de teléfono que aparece abajo b dar el número de modelo y la identificación de pieza y c describir el defecto en el producto o pieza Al solicitar servicio bajo la garantía usted debe presentar evidencia de l...

Page 9: ...e peuvent prendre feu Chauffer les huiles lentement à feu doux ou moyen 2 Toujours mettre en marche la hotte durant la cuisson à feu vif ou la cuisson d aliments à flamber 3 Nettoyer régulièrement les ventilateurs d aération On ne doit tolérer aucune accumulation de graisse sur le ventilateur ou sur le filtre 4 Utiliser une casserole de grosseur appropriée Toujours utiliser une batterie de cuisine...

Page 10: ... 2 x 4 côté large en bas SUPPORTS fixés aux autres côtés du boîtier et à l envers pour que le boîtier soit au ras du plafond fini INSTALLATION DES CONDUITS décharge de soufflerie horizontale Deux manières de raccorder les conduits à un appareil prémonté Le ventilateur peut être branché depuis l extérieur du boîtier Utiliser des connecteurs homologués UL pour les branchements conformément aux codes...

Page 11: ...INSTALLATION DES CONDUITS décharge de soufflerie verticale Raccordement de conduit typique à un ventilateur converti en décharge verticale CHAPEAU DE TOIT CONDUIT CIRCULAIRE DE 10 po 25 4 cm AVERTISSEMENT Pour diminuer les risques de décharge électrique débrancher la source d alimentation avant toute opération d entretien Pour nettoyer la grille Utiliser un accessoire d aspirateur approprié ou ret...

Page 12: ...rvice sous garantie vous devez a aviser Broan NuTone á l adresse ou numéro de téléphone mentionnée ci dessous b donner le numéro du modèle et l identification de la pièce et c décrire la nature de tout défaut dans le produit ou la pièce Au temps de demander le service sous garantie vous devez présenter une preuve de la date d achat original Aux E U comuniquez avec Broan NuTone LLC 926 West State S...

Reviews: