1.   INTRODUCTION 

Your range cooker is a semi-professional unit which gives you the power 
and flexibility to realise your full potential in the kitchen. Inevitably, during 
the cooking process, there will be heat, vapours and fumes produced. 
Your Latour extractor has been designed to complement the range cooker 
both in looks and performance in order to create the ideal environment for 
creative cooking.  

2.  EXTRACTION PERFORMANCE

 

The most important influence on the  performance of the extractor is the 
design  of  the  ducting  which  takes  the  exhaust  air  from  the  extractor  to 
the  outside  wall  louvre.  The  duct route  should  be  a  prime consideration 
during the initial stages of the kitchen design. Please note the following:  

 

This hood is designed for ducting out, i.e. duct to an outside wall. 

 

The  extractor  is  provided  with  a  spigot  suitable  for  connecting 
150mm  diameter  duct.  Twin  (2000  m

3

/hr  versions)  have  two 

blower assemblies complete with two separate exhaust spigots 
for independent ducting to the outside. 
 

 

Note: 150mm is the minimum duct diameter consistent with efficient 
extraction.  

 

The  exhaust  duct  route  length  should  be  kept  as  short  as  possible 
with as few bends as possible.  

 

The most efficient configuration is to duct straight through an outside 
wall  so  try  to  position  the  cooker  against  an  outside  wall  when 
designing your kitchen layout.  

 

Rigid 150mm round ducting or an equivalent flat channel system will 
perform best, with semi-rigid being the second best solution. Flexible 
ducting is economical but it

s use should be minimised as it gives the 

worst  performance  and  should  only  be  used  for  short  duct  runs  or 
initial  connection  and  be  pulled  taut  to  prevent  significant  losses  in 
extraction efficiency. See section 6: Additional Ducting Information 

 

A  route  with  more  than  two  90

o

  bends  will  significantly  degrade  the 

performance of the  extraction system. If possible, avoid having a 90

o

 

bend  at  the  extractor  exhaust  spigot;  keep  bend  radii  as  large  as 
possible to maintain a smooth airflow without vortices; avoid kinks in 
flexible ducting; pull flexible ducting taut over straight runs to ensure 
that the internal surface is as smooth as possible. 

 

Duct  runs  in  excess  of  5  metres  are  not  recommended  and  will 
seriously impair efficiency - if you are concerned then please call for 
advice. 

 

Please also note that a 90

o

 bend in the flexible or semi rigid ducting 

will require 215mm minimum headroom to give a smooth radius with 
no kinking. 

3.  IMPORTANT INFORMATION 

Compliance with the following notices will ensure that the installed 
product is safely installed and is safe to use. 

 

The  minimum  distance  between  the  hob  and  the  bottom  of  the 
extractor  is  essential  to  prevent  overheating  of  the  extractor  and  its 
components. 

 

The exhaust air must not be discharged into a flue  which is used for 
exhausting  fumes  from  appliances  supplied  with  energy  other  than 
electricity, e.g. oil or gas-fired central heating boilers, gas-fired water 
heaters, etc. 

 

Requirements  of  the  relevant  authorities concerning  the  discharge  of 
exhaust air must be complied with. 

 

 

Attention: This appliance requires an earth connection. 

Ensure  that  the  supply  voltage  corresponds  to  that  marked  on  the 
rating label inside the extractor. 

The  extractor  must  be  isolated  from  the  electrical  supply  before 
carrying out any cleaning or maintenance operations. 

 

Pay particular attention to fire risk when frying. To minimise the 
risk of fire, all instructions relating to cleaning the grease filters 
and removing grease deposits must be adhered to. 

 

Do not flamb

é under the extractor.

 

See Section 7 for PRODUCT GUARANTEE information. 

4.  INSTALLATION 

Do  not  throw  away  the  box  and  any  internal  packaging  until 
installation  is  fully  completed  -  
the  packaging  may  be  required  in  the 
unlikely event that hood must be returned. 

The Latour Canopy range of built in hoods are designed to slot into an 
opening made in a horizontal soffit panel - usually the underside of 
kitchen furniture, timber canopies or false/real chimney breasts. 

4.1.  Prepare Opening 

The soffit panel into which the unit is to be fixed must be between 
15mm and 22mm thick. 

Prepare an opening where the extractor is to be installed. Opening 
and Extractor dimensions are shown in Section 8: Latour Canopy 
General Arrangement Drawings. 

4.2.  Duct Installation 

Make holes, as necessary, in the walls or ceiling to take the 150mm 
diameter ducting from the extractor exhaust spigot to the outside. If 
your extractor has twin spigots you will require two separate duct 
runs to the outside 

The exhaust duct route length should be kept as short as possible 
with as few bends as possible - see Section 2. 

If terminating on an outside wall a suitable weather louvre, designed 
for connection to 150mm ducting or larger, should be fitted - an 
airbrick must never be used. A variety of ducting components and 
complete kits are available. See Section 6: Additional Ducting 
Information

For roof or chimney duct terminations please contact your supplier 
or seek alternative specialist advice. 

Recirculating Models Only 

We do not recommend recirculating air installations and they should 
be avoided wherever possible (see section 2). 

For recirculating installations you must allow for the exhaust air to 
blow back into the kitchen (or an adjacent room - e.g. utility room). 
Open topped furniture or ducting to a vent back into the room are 
common ways of achieving this as the air leaving the extractor 
spigot must have somewhere to go.  

Any ducting or openings used for return air must be at least 
equivalent in cross sectional area to that of 125mm diameter duct 
otherwise the unit may overheat and fail and you will invalidate your 
warranty. 

Additional ducting information and components can be found 
in Section 6 

 

Cooker-to-canopy clearance (minimum): 
Recommended clearance range:

 

700 mm 
750 - 850 mm

 

Canopy height (excluding Duct Spigot):

 

280 mm

 

Warning 

The  following  is  a  requirement  of  UK  and  European  legislation 
and is in the interests of your safety. 
If the room where the cooker hood is to be used contains a fossil fuel 
burning appliance such as a gas or oil central heating boiler, then its 
flue must be of the room sealed or balanced flue type. A ducted hood 
is  not  suitable  for  use  in  a  room  where  any  open  flue  is  in  use,  as 
dangerous fumes of combustion can be sucked back in to the room. 
This  would  include  the  following  open  flue  appliances 

  central 

heating  boilers,  coal  fires,  log  fires,  gas  fires,  wood  burning  stoves 
etc. Therefore, if you have an open flue fossil fuel burning appliance 
in your kitchen, you are automatically compelled to select a hood that 
is capable of working in recycling mode. 

BTH-C-950 
BTH-C-1150 
BTH-C-1400 
BTH-CT-950 
BTH-CT-1150 
BTH-CT-1400 

Latour Canopy Hood 

Installation, Operation  

& Maintenance 

Instructions 

id1080182015 pdfMachine by Broadgun Software  - a great PDF writer!  - a great PDF creator! - http://www.pdfmachine.com  http://www.broadgun.com 

Summary of Contents for BTH-C-950

Page 1: ...pply before carrying out any cleaning or maintenance operations Pay particular attention to fire risk when frying To minimise the risk of fire all instructions relating to cleaning the grease filters and removing grease deposits must be adhered to Do not flambé under the extractor See Section 7 for PRODUCT GUARANTEE information 4 INSTALLATION Do not throw away the box and any internal packaging un...

Page 2: ...er is switched off and that the ducting is securely fastened to the spigot Check if applicable that any external fans are plugged into the unit Push the extractor up through the prepared opening until the spring toggles are heard to snap over the edge of the opening we recommend that two people do this supporting one end of the extractor each Carefully release the unit ensuring that it is supporte...

Page 3: ...ailable for service during normal working hours Monday to Friday 2 The appliance is installed in accordance with these instructions and for normal domestic use 3 The guarantee does not apply if the appliance is repaired or modified by any other person than a member of our service division The guarantee does not cover misuse improper installation or any installation in commercial premises This prod...

Page 4: ...ing Maintenance Instructions W1100 Latour Built In Canopy Extractor IO M Nov 2010 docx Page 4 8 LATOUR CANOPY GENERAL ARRANGEMENT DRAWINGS Single Fan Models BTH C 950 BTH C 1150 BTH C 1400 Twin Fan Models BTH CT 950 BTH CT 1150 BTH CT 1400 ...

Page 5: ...n position carefully release the lever allowing the latch to engage Replacing Light Bulbs The unit is fitted with 20W 20 Watt 12V 12 Volt Low Voltage G4 halogen capsule bulbs lamps Replacement lamps must be of the same type G4 12V 20W Never use lamps rated at over 20W Remove the frosted glass lens by carefully prising off the lens retension ring Figure 2 taking care to support the glass so that it...

Reviews: