10
ENGLISH
6.1
Technical data of the filter cartridges
Filter cartridge
operating pressure
P 1000
P 3000
A 1000
0.2 MPa to max. 0.86 MPa
(2 bar to max. 8.6 bar)
Water intake Temperature
4°C to 30°C
Ambient tem-
perature for
operation
4°C to 40°C
storage/transport
–20°C to 50°C
Operating position
Horizontal and vertical
Water outlet connection
G3/8"
Capacity from water
hardness up to 10 °dH
at setting “A”
P 1000
Up to 1200 L
P 3000
Up to 3400 L
Capacity from water
hardness 10 to 17 °dH
at setting “B”
P 1000
Up to 600 L
P 3000
Up to 1700 L
Capacity from water
hardness 17 to 24 °dH
at setting “C”
P 1000
Up to 400 L
P 3000
Up to 1100 L
Capacity A 1000
Up to 4000 L / 6 months
Pressure loss by nominal
service flow
A 1000
0,2 bis 1,4 bar
Weight (dry/wet)
P 1000
1 kg/1.6 kg
P 3000
1.8 kg/2.8 kg
A 1000
0.5 kg/1 kg
Dimensions
(Width/Depth/
Height)
Filter
system
(filter head
with filter
cartridge)
P 1000
119/108/268 mm
P 3000
117/104/419 mm
A 1000
109/93/238 mm
Filter
cartridge
P 1000 108 mm/108 mm/259 mm
P 3000 104 mm/104 mm/410 mm
A 1000
88/88/231 mm
Installed
dimensions
(vertical
installation
with wall
mounting
bracket)
P 1000
137/130/268 mm
P 3000
137/128/419 mm
A 1000
137/120/238 mm
Filter performance
A 1000
Independent laboratory
test* reduction efficiency
at least 97% of following
substances, measured at
4000 L. Chlorine Bromo-
form, Bromodichlorometh-
ane, Tetrachlorethylene,
Dibromchlormethane,
Trichlorethylene
Particle retention NSF 42
A 1000
Class I (0.5 µm)
Chlorine reduction NSF 42
P 1000
Class I (50 %)
P 3000
A 1000
Class I (50 %)
Chlorine reduction DIN EN
14898
P 1000
Class I (> 90%)
P 3000
A 1000
Class 1 (> 90 %)
* Based on JIS S 3201 Test results (Japanese Industrial Standards)
6.2
Technical data of the 3-Way Water Filter Tap
Operating pressure
2 bar to max. 10 bar
Cold water connection
4°C to 30°C
Warm water connection
max. 60°C
Flow rate filtered water
3.5 L/min
Flow rate unfiltered
water
7 L/min (rectangle tap)
8 L/min (round tap)
Acoustics rating
Group II/-
Weight
Dimensions (Width/
Depth/Height)
Aerator
3-Way Tap rectangle
2.3 kg
18,1 cm /
26,1 cm / 29,0 cm
M24x1
M18x1
(unfil-
tered)
3-Way Tap round
2.3 kg
18,1 cm /
22,7 cm / 40,0 cm
M24x1,
8 L/min
!
The system cannot be installed with a low pressure boiler as
this might lead to water damages.
VI. Technical Data