
1
IMPORTANT
Prior to drilling in
to
walls check there
are
no hidden electric
al wires,
cables or water su
pply
pipes
1
5
6
2
4
3
1
Pack Contents
Installation Instructions
& User Guide
Prior to Installation
Installation
Please leave these instructions
with the end user
Product Code: Z2 BIB C (D5)
All products manufactured and supplied by Bristan are safe provided
they are installed, used correctly and receive regular maintenance in
accordance with these instructions.
This product has been tested to the Water Regulations Advisory
Scheme (WRAS) and satisfies the requirements of the Water Supply
(Water Fittings) Regulations 1999 and current bylaws.
For full Installation Requirements & Notes (IRN) please visit
wras.co.uk/directory.
We recommend isolation valves to be fitted to the inlet water
supplies to ensure ease of future maintenance.
Before installing these taps the water supply must be
thoroughly flushed in order to remove any swarf, solder etc.
This product must not be modified in any way as this will
invalidate the guarantee.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
If in doubt, contact a registered plumber or your Local Water
Authority or the Secretary of the Institute of Plumbing, address
as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
To replace any spare parts
for your tap, why not
scan the QR Code or
visit
www.bristan.com
and search for your product.
Spare Parts
Tools You’ll Need
Crosshead
Screwdriver
Adjustable
Spanner
Pipe Cutter
Drill
Pressure
BAR
1.0
5.0
0.2
4.0
2.0
3.0
Maximum Static Pressure: 10.0 bar
Min: 0.5 bar
Max: 5.0 bar
Dynamic Water Pressure
1.0
5.0
Pressure
BAR
4.0
2.0 3.0
0
If the supply pressure is above 3 bar, a
pressure reducing valv
ed
60˚C
65˚C
60-65
˚
C
recommended
The Flow Valve is timed and
onds
*This will vary depending on system pressure
Maximum Operating Temperature
Inlet Connections
1/2” Male BSP Tap connector
5/Ltr Flow Regulator
Pre-Fitted
x1
x1
Flow
regulator x1
Basket Filter
washer x1
Indices
x2
Red
Blue
Rear access
will be
required
Drill hole in
the wall
Place the plinth over the drilled hole
and fit taps through the wall
bask
er
washer into the
tail in the order
shown
Connect
the hot or
cold water
supplies to the
threaded tails.
If the supply
pressure is above
3 bar a pressure
reducing valve
ed
Important
5
Depending on
chosen hot
or cold water
supply
e
(supplied)
Please
ensure that
the correct
colour indice
ted
Turn on
water
supply
Turn
on water
supply for a
few minutes and
check all joints and
connections for any
leaks.
Operation
6
The tap will shut off up to
15 ± 5 seconds*
Push down
to get flow of
water