Brinkmann TS12S Operating Instructions Manual Download Page 1

BA6600 

Operating Instructions 

 Brinkmann Pumps, Inc. 

Edition

 04/2015 

Page 1 of 9 

 

BRINKMANN Immersion Pumps             

                                                             TS12

…24 

 

BRINKMANN PUMPS, Inc. 

47060 Cartier Drive 
Wixom, MI 48393 
USA 

Phone:  +1 248 926 9400 

www.brinkmannpumps.com 

Fax.:     +1 248 926 9405 

[email protected] 

 
Subject to change without prior notice.

  

Order - No.: BA6600  ENGLISH 

 

Summary of Contents for TS12S

Page 1: ...2015 Page 1 of 9 BRINKMANN Immersion Pumps TS12 24 BRINKMANN PUMPS Inc 47060 Cartier Drive Wixom MI 48393 USA Phone 1 248 926 9400 www brinkmannpumps com Fax 1 248 926 9405 sales brinkmannpumps com Su...

Page 2: ...ugal pumps where the impeller is fixed on the driving shaft extension The TS pumps are fitted out with impellers open on both sides to gain relative high pressure with compact dimension of the pump un...

Page 3: ...0 4 61 TS15S 190 220 110 7 8 12 0 42 10 0 255 7 48 190 8 66 220 26 9 12 2 27 8 12 6 1 5 1 1 68 TS21S 110 150 190 250 300 350 55 3 8 17 5 68 8 5 217 4 33 110 5 90 150 7 48 190 9 84 250 11 81 300 13 78...

Page 4: ...ards they must be guarded against accidental contact Guards for moving parts e g coupling must not be removed from the machine while in operation Any leakage of hazardous e g explosive toxic hot fluid...

Page 5: ...ll service work must be carried out by qualified service personnel Pump must be disconnected from the power source and all rotating parts must stand still Reassure that pump is disconnected from power...

Page 6: ...ere is no voltage at the terminal board Open terminal box and disconnect the power leads Empty out the pump 7 Operation Liquid level According to the drawing shown below the maximum liquid level must...

Page 7: ...above Clean pump mechanism repair pump Motor overheats High on off cycling frequency Wrong power supply voltage or cycles Insufficient cooling See above Power supply must correspond with name plate ra...

Page 8: ...n 1 Stator with terminal board 2 Pump body 3 Shaft with rotor 4 Inlet cover 5 Impeller 6 Pump plate TS15 TS24 7 End shield TS13 TS24 8 Fan 9 Fan cover 10 Terminal box 11 Ball bearing DIN 625 12 Ball b...

Page 9: ...inkmann s catalog and that any such non conforming material will be repaired or replaced as above stated BRINKMANN further warrants that it conveys good title to this product free of all liens of any...