PIEZOELECTRICITY SENSOR
INSTALLATION AND CABLE
Select a suitable tire with the small
unbalance value and mount it on the
main shaft and input the parameter
of the rim correctly.
Car mode and truck mode must be
self-calibrated separately.
Refer to the FIG9, press the key to
enter the program of [ CAL]-[ CAL]
and then press
to enter the
self-calibration[ ADD]-[ 0 ] to enter the
self-calibration
and
input
the
parameter to select the mode os car
or truck. Press and hold on
for
5 seconds and enter[ ADD]-[ 0 ]
According to the display start for one
time without adding the weight to
measure.
Spin the tire until the entire outer
indication lamp light up. Add 100g of
weight at the 12clock position outside
and re-spin to measure.
After calibration, the machine will
display [ SAV]-[ DAT ] and the
program will automatically save and
exit.
Complete the weight self-calibration.