background image

Not for 

Reproduction

Move Generator to  

Safe Operating Location

1.  Move generator outside to a flat, level surface, in an area 

that will not accumulate deadly exhaust gas. Engine exhaust 

contains carbon monoxide, a poisonous gas that could kill you 

in minutes. You CANNOT smell it, see it, or taste it. Operate 

ONLY outside far away from windows, doors and vents. Install 

carbon monoxide alarms. DO NOT run this product inside homes 

or garages, even if using fans or opening doors and windows. 

Direct exhaust AWAY from windows, doors, and vents. 

6

2.  To reduce the risk of exhaust heat or exhaust gases igniting 

nearby combustible material, keep at least 5 feet (1.5 m) 

clearance on all sides of generator, including overhead.

Start Generator

Disconnect all electrical loads from the generator. Use the 

following start instructions.

1.  Make sure unit is on a level surface.
NOTICE   Failure to start and operate the unit on a level surface 

will cause the unit not to start or shut down during operation.

2.  Turn the engine switch (D) in ON (I) position. 

7

3.  Push choke lever (E) to CHOKE ( ) position. 

8

NOTICE   To help start the engine for the very first time, after 

running out of fuel or after a long period of storage, fill fuel tank 

as described in Add Fuel. It will require more than several start 

attempts until the air in the fuel system has been purged.

4.  Grasp recoil handle and pull slowly until slight resistance is 

felt. Then pull rapidly to start engine.

5.  If engine starts, proceed to step 7. If engine fails to start, 

proceed to step 6.

6.  Move choke lever to half choke position, and pull recoil handle 

twice. If engine fails to start, repeat steps 3 thru 4.

7.  Slowly move choke lever to RUN ( ) position. If engine 

falters, move choke lever to half choke position until engine 

runs smoothly, and then to RUN ( ) position.

NOTICE   If engine starts after 3 pulls but fails to run, or if unit 

shuts down during operation, make sure unit is on a level surface 

and check for proper oil level in crankcase. This unit may be 

equipped with a low oil protection device. If so, oil must be at 

proper level for engine to start.

Plug in Items to be Powered

1.  Make sure the green output indicator light (F) comes on (it 

may take up to three seconds). 

9

2.  Let engine stabilize and warm up for a few minutes after 

starting.

3.  Plug in and turn on the desired 120 Volt AC (G), single phase, 

60 Hz electrical loads. 

9

4.  If you overload the generator, the red LED overload alarm light 

(H) comes on and cuts power to the receptacles. The green 

output indicator light will also go off. You must turn off and 

unplug all electrical loads, press the “Reset” button (J) on the 

generator control panel and then plug in and restart electrical 

loads one at a time to continue in normal operating mode. 

9

NOTICE    DO NOT connect 240 Volt loads to the 120 Volt 

receptacles.

NOTICE   DO NOT connect 3-phase loads to the generator.

NOTICE   DO NOT connect 50 Hz loads to the generator.

NOTICE   DO NOT OVERLOAD THE GENERATOR. Refer to Do 

Not Overload Generator section of Operator’s Manual. 

5.  This 12 volt DC receptacle (K) along with the USB adapter 

allows you to recharge any USB powered device with a USB 

charging cable (not included).  This receptacle is protected by 

a push to reset circuit breaker (L). 

9

Shut Down Generator

1.  Turn OFF and unplug all electrical loads from generator 

panel receptacles. NEVER start or stop engine with electrical 

devices plugged in and turned ON.

2.  Let engine run at no-load for several minutes to stabilize 

internal temperatures of engine and generator.

3.  Move engine switch (D) to the OFF (0) position. 

7

4.  To prepare for storage, refer to Operator’s Manual.

Items Included (Not Shown):

•  USB Adapter

•  Operator’s manual

•  Bottle of engine oil

•  Screwdriver

•  Oil Funnel

Items Needed (Not Included):

•  Carbon monoxide (CO) alarm(s)

•  Utility knife

•  Unleaded fuel (minimum 87 octane)

Unpack Generator

1.  Set the carton on a rigid, flat surface.

2.  Remove everything from carton except generator.

3.  Open carton completely by cutting each corner from top to 

bottom. 

4.  Ensure you have all included items prior to assembly.  

If items are damaged or missing, call 

1-800-743-4115

.

Add Engine Oil and Fuel

NOTICE   You MUST properly fill engine with oil before 

attempting to start generator.
NOTICE   DO NOT use unapproved gasoline such as E15 and 

E85. DO NOT mix oil in gasoline or modify engine to run on 

alternate fuels.

1.  Move generator outdoors to a flat, level surface. 

2.  Loosen the two maintenance cover screws (A) and remove the 

side maintenance cover. 

1

3.  Clean area around oil fill and remove yellow oil fill cap ( ). 

2

4.  Using oil funnel, slowly pour contents of provided bottle of 

engine oil into oil fill opening to the point of overflowing at oil 

fill cap. 

3

5.  Replace oil fill cap and fully tighten.

6.  Replace the maintenance cover and hand tighten the two 

maintenance cover screws.

7.  Clean area around fuel fill cap ( ), remove cap. 

4

8.  Slowly add unleaded fuel to red fuel level indicator (B) in fuel 

tank. Be careful not to fill above the indicator. This allows 

adequate space for fuel expansion. 

5

9.  Install fuel cap and let any spilled fuel evaporate before 

starting engine.

80014000, Rev A 

 

WARNING

  Damaged or overloaded electrical cords could 

overheat, arc, and burn resulting in death or serious 

injury. ONLY use cords rated for your loads. Follow all 

safeties on electrical cords. Inspect cord sets before 

each use. 

Quick Setup Guide

Inverter Generator

1

A

3

FULL OIL 

LEVEL

5

B

2

4

7

D

8

E

Have Questions?

Do not return to store.  We can help.

Call Customer Service Toll-Free 

1-800-743-4115

or vist our web site 

BRIGGSandSTRATTON.COM

 

WARNING

   Failure to read and follow the 

operator’s manual and all operating 

instructions could result in death or serious 

injury.

 

WARNING

   Engine exhaust contains carbon 

monoxide, a poisonous gas that could kill 

you in minutes. You CANNOT smell it, see 

it, or taste it. Operate ONLY outside far 

away from windows, doors and vents. Install carbon 

monoxide alarms. DO NOT run this product inside 

homes or garages, even if using fans or opening 

doors and windows. Direct exhaust AWAY from 

windows, doors, and vents.

 

WARNING

   Generator voltage could cause 

electrical shock or burn resulting in death 

or serious injury. DO NOT operate under 

wet conditions.

 

WARNING

   Fuel and its vapors are extremely 

flammable and explosive which could 

cause burns, fire or explosion resulting 

in death or serious injury. Turn generator 

engine OFF and let it cool at least 2 minutes before 

removing fuel cap. Let spilled fuel evaporate 

before starting engine. Always allow space for fuel 

expansion.

 

WARNING

   Hot exhaust and reflective exhaust 

gases could cause burns and fires 

resulting in death or serious injury. Keep 

at least 5 ft. (1.5 m) clearance from any 

combustibles or structures, including overhead.

© 2017 Briggs & Stratton Corporation. All rights reserved.

Every effort has been made to ensure that the information in this document is accurate and correct. However, we reserve the right to alter or otherwise improve the product and this document at any time without prior notice and without incurring obligation.

This generator is certified in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-04 (motors and generators) and rated in accordance with PGMA (Portable Generator Manufacturers’ Association) standard PGMA G200 

(Standard for Testing and Validating Performance of Portable Generators).

6

Install carbon monoxide alarms inside 
your home. Without working carbon
monoxide alarms, you will not realize
you are getting sick and dying from
carbon monoxide poisoning

.

CARBON MONOXIDE ALARM(S)

USE OUTDOORS - AVOID CARBON MONOXIDE POISONING 

point away

from home

MUFFLER

9

H

F

G

L

J

K

Reviews: