Especificações do produto

Modelo(s) 030566, 030596

Vatagem de partida  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.500 watts
Vatagem nominal* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.300 watts
Voltagem da saída de CA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 volts
Corrente de carga a 230 volts CA   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 amps
Frequência  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz
Fase    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Monofásico
Capacidade de combustível  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 l (4 gal)
Cilindrada do motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9,95 ci (163 cc)
Capacidade de óleo  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 - 20 oz (0,54 - 0,59 l)
Vão da vela de ignição  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,03 pol (0,76 mm)
Torque da vela de ignição  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 lb-pol (20 Nm)
Abertura válvula de entrada  . . . . . . . . . . . . . . . . . . . . 0,004 - 0,006 pol (0,1 - 0,15 mm)
Folga da válvula de exaustão  . . . . . . . . . . . . . . . . . . . 0,006 - 0,008 pol (0,15 - 0,2 mm)

Modelo(s) 030570, 030597

Vatagem de partida  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.000 watts
Vatagem nominal* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.500 watts
Voltagem da saída de CA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 volts
Corrente de carga a 230 volts CA   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15,2 amps
Frequência  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz
Fase    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Monofásico
Capacidade de combustível  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,6 gal (25 l)
Cilindrada do motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16,48 ci (270 cc)
Capacidade de óleo  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 - 37 oz (1,05 - 1,09 l)
Vão da vela de ignição  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,03 pol (0,76 mm)
Torque da vela de ignição  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275 lb-pol (31 Nm)
Abertura válvula de entrada  . . . . . . . . . . . . . . . . . . . 0,005 - 0,007 pol (0,13 - 0,18 mm)
Folga da válvula de exaustão  . . . . . . . . . . . . . . . . . . 0,005 - 0,007 pol (0,13 - 0,18 mm)

Modelo(s) 030576, 030583, 030598, 030599

Vatagem de partida  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.500 watts
Vatagem nominal* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.000 watts
Voltagem da saída de CA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 volts
Corrente de carga a 230 volts CA   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 amps
Frequência  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz
Fase    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Monofásico
Capacidade de combustível  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,6 gal (25 l)
Cilindrada do motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25,63 ci (420 cc)
Capacidade de óleo  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 - 37 oz (1,05 - 1,09 l)
Vão da vela de ignição  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,03 pol (0,76 mm)
Torque da vela de ignição  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275 lb-pol (31 Nm)
Abertura válvula de entrada  . . . . . . . . . . . . . . . . . . . 0,005 - 0,007 pol (0,13 - 0,18 mm)
Folga da válvula de exaustão  . . . . . . . . . . . . . . . . . . 0,005 - 0,007 pol (0,13 - 0,18 mm)

Modelo(s) 030588

Vatagem de partida  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.500 watts
Vatagem nominal* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.300 watts
Voltagem da saída de CA  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 volts
Corrente de carga a 115 volts CA   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 amps
Frequência  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz
Fase    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Monofásico
Capacidade de combustível  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4,0 gal (15 l)
Cilindrada do motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9,95 ci (163 cc)
Capacidade de óleo  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 - 20 oz (0,54 - 0,59 l)
Vão da vela de ignição  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,03 pol (0,76 mm)
Torque da vela de ignição  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 lb-pol (20 Nm)
Abertura válvula de entrada  . . . . . . . . . . . . . . . . . . . . 0,004 - 0,006 pol (0,1 - 0,15 mm)
Folga da válvula de exaustão  . . . . . . . . . . . . . . . . . . . 0,006 - 0,008 pol (0,15 - 0,2 mm)

Modelo(s) 030589

Vatagem de partida  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.000 watts
Vatagem nominal* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.500 watts
Voltagem da saída de CA  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 / 230 volts
Corrente de carga a 115 volts CA   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30,4 amps
Corrente de carga a 230 volts CA   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15,2 amps
Frequência  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz
Fase    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Monofásico
Capacidade de combustível  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,6 gal (25 l
Cilindrada do motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16,48 ci (270 cc)
Capacidade de óleo  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 - 37 oz (1,05 - 1,09 l)
Vão da vela de ignição  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,03 pol (0,76 mm)
Torque da vela de ignição  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275 lb-pol (31 Nm)
Abertura válvula de entrada  . . . . . . . . . . . . . . . . . . . 0,005 - 0,007 pol (0,13 - 0,18 mm)
Folga da válvula de exaustão  . . . . . . . . . . . . . . . . . . 0,005 - 0,007 pol (0,13 - 0,18 mm)

Modelo(s) 030590, 030591

Vatagem de partida  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.500 watts
Vatagem nominal* . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.000 watts
Voltagem da saída de CA  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 / 230 volts
Corrente de carga a 115 volts CA   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52,1 amps
Corrente de carga a 230 volts CA   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 amps
Frequência  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 Hz
Fase    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Monofásico
Capacidade de combustível  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6,6 gal (25 l)
Cilindrada do motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25,63 ci (420 cc)
Capacidade de óleo  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 - 37 oz (1,05 - 1,09 l)
Vão da vela de ignição  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,03 pol (0,76 mm)
Torque da vela de ignição  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275 lb-pol (31 Nm)
Abertura válvula de entrada  . . . . . . . . . . . . . . . . . . . 0,005 - 0,007 pol (0,13 - 0,18 mm)
Folga da válvula de exaustão  . . . . . . . . . . . . . . . . . . 0,005 - 0,007 pol (0,13 - 0,18 mm)

Classificações de potência: 

A potência bruta para os modelos de motor a gás individuais é classificada conforme o código J1940 (Small Engine Power & Torque Rating 

Procedure – Procedimento de Classificação de Potência e Torque para Pequenos Motores) da SAE (Society of Automotive Engineers – Sociedade de Engenheiros Automotivos) e 

o desempenho da classificação foi obtido e corrigido de acordo com o código SAE J1995 (Revisão de 2002-05). Os valores de torque são derivados a 3.060 RPM; os valores de 

cavalo-vapor são derivados a 3.600 RPM. As curvas de potência bruta podem ser vistas em www.BRIGGSandSTRATTON.COM. Os valores de potência nominal são obtidos com 

os sistemas de exaustão e de filtragem de ar instalados, enquanto que os valores de potência bruta são obtidos sem que esses acessórios estejam instalados. A potência bruta 

real do motor será maior do que a potência nominal e é afetada, entre outras coisas, pelas condições do ambiente operacional e variações que existem entre um motor e outro. 

Devido à grande variedade de produtos que utilizam motores, um motor a gasolina pode não desenvolver a potência bruta especificada quando for instalado em um determinado 

tipo de equipamento. Esta diferença se deve a vários fatores, incluindo mas não se limitando a acessórios (filtro de ar, escapamento, carga, arrefecimento, carburador, bomba 

de combustível, etc.), limitações da aplicação, condições do ambiente operacional (temperatura, umidade, altitude), e variações que existem entre um motor e outro. Devido às 

limitações de fabricação e capacidade, a Briggs & Stratton pode substituir o motor desta Série por outro de potência maior.
*  Este gerador é classificado de acordo com ISO 8528 G1.

Peças de serviço comuns

Filtro de ar - modelo de motor 106200  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 591717
Filtro de ar - modelo de motor 160000  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 591778
Filtro de ar - modelo de motor 250000  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 591778
Vela de ignição - modelo de motor 106200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 491055
Vela de ignição - modelo de motor 160000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 797235
Vela de ignição - modelo de motor 250000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 797235

Summary of Contents for GS2500

Page 1: ...o n BRIGGS STRATTON CORPORATION MILWAUKEE WISCONSIN U S A Manual No 381491 Revision C GS2500 GS4000 GS6500 GS6500E Portable Generator Gerador Port til Generador port til Operator s Manual Manual do O...

Page 2: ...N o t f o r R e p r o d u c t i o n 2 BRIGGSandSTRATTON COM 2 B A 4 A 3 A 5 A B C 1 B D F T S L G H U C K P N A M E R J...

Page 3: ...N o t f o r R e p r o d u c t i o n 3 3 6 8 7 9 10 11 C B A A A A...

Page 4: ...operate this equipment Save these original instructions for future reference This generator requires final assembly before use Refer to the Assembly section of this manual for instructions on final a...

Page 5: ...a doctor You may have carbon monoxide poisoning Operate this product ONLY outside far away from windows doors and vents to reduce the risk of carbon monoxide gas from accumulating and potentially bein...

Page 6: ...mobile equipment marine applications or enclosure DO NOT tip engine or equipment at angle which causes fuel to spill DO NOT stop engine by moving choke control to Choke position WHEN TRANSPORTING MOV...

Page 7: ...ines attach the negative battery cable to the battery as follows 1 Cut off tie wrap securing loose end of negative black cable 2 Using an 8 mm socket wrench remove screw C lock washer C and flat washe...

Page 8: ...ke sure unit is on a level surface and check for proper oil level in crankcase This unit is equipped with a low oil protection device If so oil must be at proper level for engine to start WARNING Exha...

Page 9: ...level is too low a switch will stop the engine and activate a warning light U on the generator If the oil level is too low when starting the engine the switch will activate the warning light If the wa...

Page 10: ...that all electrical devices are disconnected from the generator outlets 2 Start the engine see the How to Start the Engine section 3 Connect the electrical device that requires the most watts load 4 L...

Page 11: ...gine controls clean Keep the area around and behind the muffler free from any combustible debris Inspect cooling air slots and openings on generator These openings must be kept clean and unobstructed...

Page 12: ...ould cause the engine to not start or hard starting DO NOT overfill If over the full mark on dipstick drain oil to reduce oil level to full mark on dipstick 4 Replace and tighten oil cap dipstick Chan...

Page 13: ...keep fuel fresh use Briggs Stratton Advanced Formula Fuel Treatment Stabilizer available wherever Briggs Stratton genuine service parts are sold There is no need to drain gasoline from the engine if a...

Page 14: ...take valve stuck open or closed 13 Engine has lost compression 14 Electric start switch in off position 15 Battery discharged 1 Turn fuel valve to on I position 2 Fill crankcase to proper level or pla...

Page 15: ...270 cc Oil Capacity 35 37 oz 1 05 1 09 L Spark Plug Gap 0 030 in 0 76 mm Spark Plug Torque 275 lb in 31 Nm Intake Valve Clearance 0 005 0 007 in 0 13 0 18 mm Exhaust Valve Clearance 0 005 0 007 in 0...

Page 16: ...ty are not applicable to this warranty NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT IF YOU DO NOT PROVIDE PROOF OF THE INITI...

Page 17: ...N o t f o r R e p r o d u c t i o n 17...

Page 18: ...stru es originais para refer ncia futura Este gerador exige uma montagem final antes do uso Consulte a se o Montagem deste manual de instru es para obter os procedimentos da montagem final Siga as ins...

Page 19: ...ento por mon xido de carbono Opere este produto APENAS ao ar livre longe de janelas portas e passagens de ventila o para evitar o risco de ac mulo de mon xido de carbono e sua entrada em reas ocupadas...

Page 20: ...os m veis aplica es mar timas ou espa os fechados N O incline o motor ou o equipamento para um ngulo que poder provocar o derramamento de combust vel N O pare o motor movendo o controle do afogador pa...

Page 21: ...a adeira que prende a extremidade solta do cabo negativo preto 2 Usando uma chave soquete de 8 mm remova o parafuso C a arruela de press o C e a arruela plana C em um terminal negativo da bateria A 3...

Page 22: ...c rter Esta unidade equipada com um dispositivo de prote o contra falta de leo Em caso positivo o leo deve estar no n vel adequado para que o motor ligue ADVERT NCIA O calor e os gases da exaust o po...

Page 23: ...r Se o n vel de leo estiver baixo demais ao ligar o motor a chave ativar a luz de advert ncia Se a luz de advert ncia estiver ativada certifique se de que a unidade est sobre uma superf cie nivelada e...

Page 24: ...partida no motor 3 Conecte o dispositivo el trico que exige mais watts carga 4 Aguarde a estabiliza o da sa da do gerador funcionamento homog neo e constante do motor 5 Conecte o pr ximo dispositivo...

Page 25: ...evem ser mantidas limpas e desobstru das As pe as do motor devem ser mantidas limpas para reduzir o risco de superaquecimento e igni o dos res duos acumulados Use um pano mido para limpar as superf ci...

Page 26: ...reta de n vel N O PERMITA que transborde AVISO O preenchimento com leo em excesso pode fazer com que o motor n o arranque ou provocar uma partida dif cil N O PERMITA que transborde Se acima da marca d...

Page 27: ...Para manter o combust vel em condi es ideais use o Briggs Stratton Advanced Formula Fuel Treatment Stabilizer dispon vel onde quer que pe as de reposi o genu nas da Briggs Stratton sejam vendidas N o...

Page 28: ...motor perdeu a compress o 14 Interruptor de partida el trica na posi o desligado 15 Bateria descarregada 1 Gire a v lvula do combust vel para a posi o I 2 Preencha o c rter at o n vel adequado ou rep...

Page 29: ...pol 0 76 mm Torque da vela de igni o 275 lb pol 31 Nm Abertura v lvula de entrada 0 005 0 007 pol 0 13 0 18 mm Folga da v lvula de exaust o 0 005 0 007 pol 0 13 0 18 mm Modelo s 030590 030591 Vatagem...

Page 30: ...quipamentos usados como fonte de energia principal em vez da rede el trica N O NECESS RIO NENHUM REGISTRO PARA OBTER GARANTIA DOS PRODUTOS BRIGSS STRATTON BASTA GUARDAR SEU RECIBO DE PROVA DE COMPRA S...

Page 31: ...N o t f o r R e p r o d u c t i o n 17 17...

Page 32: ...ciones para poder consultarlas en el futuro Debe montar este generador antes de utilizarlo Para obtener instrucciones sobre el procedimiento de montaje final consulte la secci n Montaje de este manual...

Page 33: ...ir el riesgo de que se acumule el mon xido de carbono y de que pueda introducirse en espacios habitados Instale alarmas de detecci n de mon xido de carbono con bater a o con alimentaci n el ctrica y b...

Page 34: ...obertizos para coches porches equipos m viles embarcaciones o recintos NO incline el motor o el generador con un ngulo que haga que se derrame el combustible NO pare el motor desplazando el control de...

Page 35: ...el seguro del envoltorio que sujeta el extremo suelto del cable negativo negro 2 Con una llave de tubo de 8 mm retire el tornillo C la arandela de seguridad C y la arandela plana C o del polo negativo...

Page 36: ...nivel del aceite en el c rter sea el adecuado Este generador est equipado con un dispositivo de protecci n para un nivel bajo de aceite Por lo tanto para que arranque el nivel debe superar el m nimo A...

Page 37: ...se arranca el motor el interruptor activar el LED de advertencia Si el LED de advertencia se ha activado aseg rese de que la unidad est colocada sobre una superficie plana y compruebe que el nivel de...

Page 38: ...dor 2 Arranque el motor consulte la secci n C mo arrancar el motor 3 Conecte el dispositivo el ctrico que requiera m s potencia carga 4 Deje que la salida del generador se estabilice el motor marcha c...

Page 39: ...e refrigeraci n del generador Deben estar limpias y despejadas Mantenga limpios los componentes del motor con el fin de reducir el riesgo de sobrecalentamiento e ignici n de los residuos acumulados Ut...

Page 40: ...lla NO llene en exceso AVISO El llenado de aceite en exceso podr a impedir el arranque del motor o provocar dificultades de arranque NO llene en exceso Si el nivel de aceite est por encima de la marca...

Page 41: ...estado use Briggs amp Stratton Advanced Formula Fuel Treatment amp Stabilizer disponible donde sea que se vendan piezas de servicio originales de Briggs amp Stratton No es necesario vaciar el motor d...

Page 42: ...14 Interruptor de arranque el ctrico en la posici n de apagado 15 Bater a descargada 1 Gire la llave de paso de combustible a la posici n de abertura I 2 Llene el c rter hasta el nivel adecuado o colo...

Page 43: ...30590 030591 Potencia inicial 6 500 vatios Potencia nominal 6 000 vatios Voltaje de salida de CA 115 230 voltios Corriente de carga en 115 voltios CA 52 1 A Corriente de carga en 230 voltios CA 26 0 A...

Page 44: ...A GARANT A EN LOS PRODUCTOS DE BRIGGS AMP STRATTON GUARDE LA FACTURA O EL COMPROBANTE DE LA COMPRA SI NO DISPONE DE UN JUSTIFICANTE DE LA FECHA DE COMPRA INICIAL EN EL MOMENTO DE SOLICITAR SERVICIO DE...

Page 45: ...N o t f o r R e p r o d u c t i o n 17 17...

Page 46: ...GGSandSTRATTON COM 4 BRIGGSandSTRATTON COM Briggs Stratton Briggs Stratton Briggs Stratton Briggs Stratton Briggs Stratton BRIGGSandSTRATTON COM 5 7 7 8 11 14 15 16 2017 Briggs Stratton Corporation BR...

Page 47: ...N o t f o r R e p r o d u c t i o n 5 5 RCD...

Page 48: ...N o t f o r R e p r o d u c t i o n 6 BRIGGSandSTRATTON COM 6 BRIGGSandSTRATTON COM 2 5 1 5...

Page 49: ...i o n 7 7 Briggs Stratton 1 2 3 2 4 1 2 3 4 A 4 2 A 5 2 B 6 1 3 87 87 AKI 91 RON 10 E15 E85 EM 1 2 1 C 3 A 3 5 000 1 524 85 85 AKI 89 RON Briggs Stratton 2 500 762 5 1 2 8 A C C C 3 B 4 5 1 A B C D E...

Page 50: ...N o t f o r R e p r o d u c t i o n 8 BRIGGSandSTRATTON COM 8 BRIGGSandSTRATTON COM 6 7 1 1 2 L I 3 S 4A T 15 1 6 5 4B I M 6 5 5 I 4A 3 4 6 3 5 1 5 RCD...

Page 51: ...N o t f o r R e p r o d u c t i o n 9 9 1 1 2 H 3 4 F 5 6 8 9 1 2 3 4 T 1 U RCD...

Page 52: ...5 600 2155 1 2 3 4 5 6 7 300 600 500 500 500 180 75 75 1555 600 75 75 500 500 800 1200 18 cf 800 1600 1 3 1000 2000 10 000 BTU 1200 1800 300 600 1 2 800 1300 1000 1000 1500 1500 DVD CD 100 VCR 100 450...

Page 53: ...N o t f o r R e p r o d u c t i o n 11 11 8 11 1 11 A 2 11 B 3 1 2 8 A 3 4 5 5 8 25 50 100...

Page 54: ...o r R e p r o d u c t i o n 12 BRIGGSandSTRATTON COM 12 BRIGGSandSTRATTON COM Briggs Stratton Briggs Stratton SF SG SH SJ 4 C 40 F SAE 30 27 C 80 F 10W30 1 2 4 8 1 2 4 A 3 2 B 1 2 3 4 1 2 3 1 K 4 5 6...

Page 55: ...N o t f o r R e p r o d u c t i o n 13 13 9 1 2 3 4 5 10 1 A 2 B 3 4 5 C 6 Briggs Stratton 30 30 Briggs Stratton 2 1 2 3 4 5 1 5 2...

Page 56: ...n 14 BRIGGSandSTRATTON COM 14 BRIGGSandSTRATTON COM 1 2 3 4 1 2 3 4 1 2 3 4 5 1 2 3 4 5 1 O 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 I 2 3 4 5 6 7 8 9 10 5 11 12 13 14 15 1 2 3 1 2 3 1 2 1 2 2 300 3 500 6...

Page 57: ...7 0 13 0 18 0 005 0 007 0 13 0 18 030588 2 500 2 300 115 115 20 0 60 4 0 15 9 95 ci 163 cc 18 20 0 54 0 59 0 030 0 76 180 20 0 004 0 006 0 10 0 15 0 006 0 008 0 15 0 20 030589 4 000 3 500 115 230 115...

Page 58: ...com BRIGGSandSTRATTON COM 1300 274 447 salesenquires briggsandstratton com au Briggs Stratton Australia Pty Ltd 1 Moorebank Avenue NSW Australia 2170 BRIGGS STRATTON O 198195C D 08 24 2012 BRIGGS STR...

Page 59: ...N o t f o r R e p r o d u c t i o n 17 17...

Page 60: ...GGSandSTRATTON COM Briggs Stratton Briggs Stratton Briggs Stratton Briggs Stratton Briggs Stratton BRIGGSandSTRATTON COM 5 7 7 8 11 14 15 16 Copyright 2017 Briggs Stratton Corporation Milwaukee WI USA...

Page 61: ...N o t f o r R e p r o d u c t i o n 5 5...

Page 62: ...N o t f o r R e p r o d u c t i o n 6 BRIGGSandSTRATTON COM 6 BRIGGSandSTRATTON COM W W OFF ON 2 1 5m 5 ft...

Page 63: ...D 1 2 3 2 4 1 2 3 4 A 4 2 A 5 FULL 2 B FULL 6 1 3 87 87 AKI 91 RON 10 E15 E85 EM Engine Modifications 1 2 1 C 3 A 3 5 000 ft 1524 m 85 85 AKI 89 RON Briggs Stratton 2 500 ft 762 m 5 1 2 8 mm C C C A 3...

Page 64: ...N o t f o r R e p r o d u c t i o n 8 BRIGGSandSTRATTON COM 8 BRIGGSandSTRATTON COM AC AC 6 7 1 1 2 L I 3 S 4A T 15 1 6 5 4B I M 6 5 5 I 4A 3 4 6 3 1 5m 5 ft...

Page 65: ...N o t f o r R e p r o d u c t i o n 9 9 1 AC 1 2 H 3 4 AC F 5 W W 6 8 9 1 2 3 4 T 1 U ADD FULL ADD FULL Briggs Stratton...

Page 66: ...3 4 5 6 7 W W OFF ON W W 300 600 500 500 TV 500 180 75W 75 1555 W 600 W W W W 75W 75 500 500 800 1200 18 cf 800 1600 1 3 hp 1000 2000 AC 10 000 BTU 1200 1800 300 600 1 2 hp 800 1300 1000 W 1000 1500...

Page 67: ...N o t f o r R e p r o d u c t i o n 11 11 1 8 11 1 11 A 2 11 B 3 1 2 8 A 3 4 5 5 8 25 50 100...

Page 68: ...r o d u c t i o n 12 BRIGGSandSTRATTON COM 12 BRIGGSandSTRATTON COM Briggs Stratton Briggs Stratton SF SG SH SJ 4 C 40 F SAE 30 27 C 80 F 10W30 1 2 4 8 1 2 4 A 3 FULL 2 B 1 2 3 FULL FULL FULL 4 1 2 3...

Page 69: ...N o t f o r R e p r o d u c t i o n 13 13 9 1 2 3 4 5 10 1 A 2 B 3 4 5 C 6 Briggs Stratton 30 30 Briggs Stratton Briggs Stratton Advanced Formula Fuel Treatment Stabilizer 2 1 2 3 4 1 5 m 5 ft 2...

Page 70: ...RIGGSandSTRATTON COM 14 BRIGGSandSTRATTON COM AC 1 2 3 4 1 2 3 4 1 2 3 4 5 1 2 3 4 5 1 O 2 3 4 5 6 7 8 9 10 11 12 13 14 OFF 15 1 I 2 3 4 5 6 7 8 9 10 5 11 12 13 14 15 1 2 3 1 2 3 1 2 1 2 2 300 W 3 500...

Page 71: ...mm 030588 W 2 500 W W 2 300 W AC 115 V 115 V AC 20 0 Amps 60 Hz 4 0 gal 15 L 9 95 ci 163 cc 18 20 oz 0 54 0 59 L 0 030 in 0 76 mm 180 lb in 20 Nm 0 004 0 006 in 0 10 0 15 mm 0 006 0 203 mm 0 15 0 20...

Page 72: ...GSandSTRATTON COM 1300 274 447 salesenquires briggsandstratton com au Briggs Stratton Australia Pty Ltd 1 Moorebank Avenue NSW Australia 2170 BRIGGS STRATTON O 198195K Rev D 2012 08 24 BRIGGS STRATTON...

Reviews: