10
Briggs & Stratton Power Products Home Generator System
Owners Manual
SPECIFICATIONS
Maximum Surge Watts . . . . . . . . . . . . . . . . .8,500 watts
Continuous Wattage Capacity . . . . . . . . . . .5,500 watts
Power Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.0
Rated Maximum Continuous AC Load Current:
At 120 Volts . . . . . . . . . . . . . . . . . . . . . . .45.8 Amps
At 240 Volts . . . . . . . . . . . . . . . . . . . . . . .22.9 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . 7 U.S. gallons
Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . 197 lbs.
GENERAL MAINTENANCE
RECOMMENDATIONS
The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. Never operate a
damaged or defective generator.
Engine Maintenance
See engine owner’s manual for instructions.
If you need service for your engine, you need to determine
the engine identification number.To do so, remove the
rocker arm cover hood, item number 55 shown on
page 16, by removing the four nuts and washers holding it
in place.The engine model-type-trim number is stamped on
the side of the inner cover attached to the engine. Have
this number in hand when you call the engine service
center for assistance.
CAUTION!
Avoid prolonged or repeated skin
contact with used motor oil. Used motor oil has
been shown to cause skin cancer in certain
laboratory animals.Thoroughly wash exposed areas
with soap and water.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: Do Not use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
To Clean the Generator
CAUTION!
Never insert any object or tool
through the air cooling slots, even if the engine is
not running.
• Use a damp cloth to wipe exterior surfaces clean.
• A soft bristle brush may be used to loosen caked on dirt
or oil.
• A vacuum cleaner may be used to pick up loose dirt and
debris.
• Low pressure air (not to exceed 25 psi) may be used to
blow away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.
Summary of Contents for 190477GS
Page 13: ...13 Briggs Stratton Power Products Home Generator System Owners Manual NOTES...
Page 14: ...14 Briggs Stratton Power Products Home Generator System Owners Manual SCHEMATIC...
Page 15: ...15 Briggs Stratton Power Products Home Generator System Owners Manual WIRING DIAGRAM...
Page 16: ...16 Briggs Stratton Power Products Home Generator System Owners Manual EXPLODED VIEW MAIN UNIT...
Page 40: ...Groupe lectrog ne de la Gamme de Produits Briggs Stratton Manuel d Utilisation 40 REMARQUES...