Briggs & Stratton Power Products Home Generator System

Owners Manual

INTRODUCTION

Briggs and Stratton has made every effort to provide for a
safe, streamlined and cost-effective installation. Because
each installation is unique, it is impossible to know of and
advise the trade of all conceivable procedures and methods
by which installation might be achieved. Neither could we
know of possible hazards and/or the results of each
method or procedure. For these reasons,

Only current qualified electrical contractors

should attempt HGS Installations.

Installations must strictly comply with

all applicable codes, industry standards

and regulations.

Your Briggs & Stratton Home Generator System is supplied
with this “Owners Manual” and a separate “Installation
Manual” (part number 190854).These are both important
documents and should be retained by the owner after the
installation has been completed.

WARNING!

Per National Electric Code,

connection of a generator to any electrical circuit
normally powered by an electric utility must be by
means of approved transfer switch equipment so as
to isolate the electrical circuit from the utility
distribution system when the generator is operating.
Failure to isolate the electrical circuits by such
means may result in injury or death to utility power
workers due to backfeed of electrical energy.

The semi-automatic transfer switch is suitable for use in
accordance with Article 702 of the National Electric Code,
ANSI/NFPA 70.This switch is suitable for use on a circuit
capable of delivering not more than 10000A RMS,
symmetrical current, 120/240V, when installed on the load
side of appropriate branch circuit. For indoor use only.The
connection box is a NEMA type 3R, intended for outdoor
use.

Installation Assistance

For the Home or Business Owner:

To help you make informed choices and communicate
effectively with your installation contractor(s),

Read and understand the

Owner Orientation Section of this manual

BEFORE contracting or starting

your HGS installation.

To arrange for proper installation, contact the store at which
you purchased your Briggs & Stratton Home Generator
System, your dealer, or your utility power provider.

The HGS Warranty is VOID unless the system

is installed by certified electrical professionals.

For the Installing Dealer/Contractor:

For most applications, the Installation Manual contains all
the information required to properly install and start the
Home Generator System.This Owner’s Manual describes
essential circuit selection, routine operation and owner
maintenance procedures.

If you need more information, call 1-800-743-4115, between
8:00 AM and 5:00 PM CT.

OWNER ORIENTATION

This section provides Home Generator System owners
with the information necessary to achieve the most
satisfactory and cost effective installation possible.

The illustrations are for typical circumstances and are
meant to familiarize you with the installation options
available with your Home Generator System. A thorough
understanding of these options will provide fundamental
control over the cost of your installation, as well as ensure
your final satisfaction and security.

Local codes, appearance, noise levels, and distances are the
factors that must be considered when negotiating with an
installation professional. Remember that as the distance
from the existing electrical service and wiring materials
must be allowed for.This is necessary to comply with local
codes and overcome electrical voltage drops.

The factors mentioned above will have a direct
affect on the overall price of your Home Generator
System installation.

NOTE: In some areas you may need to acquire electrical
permits for installing the Home Generator System, and
permits for noise allowances.Your installer should check
your local codes AND obtain the permits before installing
the system.

Summary of Contents for 1678

Page 1: ...da es justa un momento lejos Vous avez des questions Vous n avez pas besoin d aller loin pour trouver de l aide Call Home Standby Helpline Llamada L nea Directa de Reserva de Hogar Appelez Ligne Direc...

Page 2: ...symbol indicates a situation that could result in equipment damage Follow safety messages to avoid or reduce the risk of injury or death The engine exhaust from this product contains chemicals known t...

Page 3: ...id and is extremely caustic Contact with battery fluid will cause severe chemical burns DANGER Do not touch hot surfaces Allow equipment to cool before touching Running engines produce heat Temperatur...

Page 4: ...formed choices and communicate effectively with your installation contractor s Read and understand the Owner Orientation Section of this manual BEFORE contracting or starting your HGS installation To...

Page 5: ...92 cm from combustible material NFPA 37 Leave at least 3 ft 92 cm all around for access to the generator The unit s exhaust port must be at least 5 ft 152 cm from any building opening window door vent...

Page 6: ...hts can be taken from light bulbs The rated wattage of tools appliances and motors can usually be found on a data plate or decal affixed to the device If the appliance tool or motor does not give watt...

Page 7: ...t the power transfer system components and conduit 3 Conduit fittings wire nuts and insulated copper wire for connecting the semi automatic transfer switch to the outside connection box Delivery Inspe...

Page 8: ...n valve facing outward 3B Place one end of the needle nose pliers on the bottom of the axle and the other end of the pliers on top of the e ring Seat the e ring by pressing the pliers closed 4 Slide t...

Page 9: ...fill fuel tank when engine is running or hot Allow unit to cool for two minutes before refueling Do Not light a cigarette or smoke when filling the fuel tank WARNING Do Not overfill the fuel tank Alwa...

Page 10: ...of dirt and dust that gets in the engine Choke Lever Used when starting a cold engine Circuit Breakers AC Each receptacle is provided with a circuit breaker to protect the generator against electrical...

Page 11: ...rovided Figure 7 to make the grounding attachment Connecting a No 12 AWG American Wire Gauge stranded copper wire to the grounding wing nut and to an earth driven copper or brass grounding rod electro...

Page 12: ...o Not connect 3 phase loads to the generator Do Not connect 50 Hz loads to the generator DO NOT OVERLOAD THE GENERATOR When not used with the semi automatic transfer switch add up the rated watts or a...

Page 13: ...rator is running How to Use the Battery Charger Use the battery float charger jack to keep the starting battery charged and ready for use Battery charging should be done in a dry location such as insi...

Page 14: ...the engine as described in this manual 2 Plug in and turn on the first load preferably the largest load you have 3 Permit the generator output to stabilize engine runs smoothly and attached device ope...

Page 15: ...enerator control panel Start the generator using instructions given in the section Operating the Generator on page 11 5 Close the generators main circuit breaker 6 After a ten second delay the transfe...

Page 16: ...the house connector box see Figure 15 4 At the generator connect the other end of the power cord to the generator see Figure 16 Make sure the circuit breaker on the generator is open OFF 5 Start the g...

Page 17: ...ON T POLLUTE CONSERVE RESOURCES RETURN USED OIL TO COLLECTION CENTERS Generator Maintenance Generator maintenance consists of keeping the unit clean and dry Operate and store the unit in a clean dry e...

Page 18: ...ge See engine owner s manual for instructions Other Storage Tips To prevent gum from forming in fuel system or on essential carburetor parts add fuel stabilizer into fuel tank and fill with fresh gaso...

Page 19: ...gasoline 9 Overchoking 10 Low oil level 11 Excessively rich fuel mixture 12 Intake valve stuck open or closed 13 Engine has lost compression 14 Failed battery 1 Set switch to On 2 Turn fuel valve to...

Page 20: ...20 Briggs Stratton Power Products Home Generator System Owners Manual NOTES...

Reviews: