186
9
Disassemble Oil Gard® System (161400)
1. Disconne ct wire (
A
) from float assembly
terminal and remove mounting screws
([
B
] Fig. 28).
Fig. 28
2. Remove float assembly ([
A
] Fig. 29) from
cylinder.
Fig. 29
To service warning light,
1. Disconnect wire connector and remove
light from control panel.
2. Remove air cleaner to gain access to light
(if so equipped).
Inspect Oil Gard® System (16140 0)
1. Inspect float assembly for cracks in
housing and float.
2. Check Oil Gard® switch operation by
connecting a continuity tester to the wire
terminal and ground clip.
3. In the normal upright position, the tester
should read continuity.
4. Turn the float assembly upside down.
5. The tester should read no continuity.
Assemble Oil Gard® System (161400)
Refer to Fig. 29
1. Install serviceable light assembly in
control panel.
2. Install new gasket ([
A
] Fig. 29 ) with
sealant bead toward cylinder and float
assembly.
3. Apply sealant to screw threads.
4. Install mounting screws.
5. Torque to listed value.
See SECTION 14-
ENGINE SPECIFICATION.
6. Install wire terminal.
f61p28
f62p28
Summary of Contents for 115400
Page 5: ...4 1 ...
Page 10: ...9 1 BRIGGS STRATTON NUMERICAL IDENTIFICATION SYSTEM ...
Page 15: ...14 1 Fig 7 Fig 8 Fig 9 Fig 10 ...
Page 29: ...28 1 ...
Page 77: ...76 4 ...
Page 87: ...86 4 ...
Page 89: ...88 5 ...
Page 135: ...134 6 ...
Page 161: ...160 7 ...
Page 163: ...162 8 ...
Page 179: ...178 9 ...
Page 189: ...188 10 ...
Page 202: ...201 10 Fig 34 Fig 35 Fig 36 Fig 37 Fig 38 Fig 39 ...
Page 207: ...206 10 ...
Page 209: ...208 11 ...
Page 219: ...218 11 ...
Page 221: ...220 12 ...
Page 229: ...228 12 ...
Page 231: ...230 13 ...
Page 281: ...280 14 ...