100
5
Fig. 29
The float hinge pin ([
A
] Fig. 30) is a wedge fit.
5. Tap the small end of the pin (
B
) with a
center punch until it is loo se.
6. Remove pin (
A
) and remove the float ([
C
]
Fig. 30) and inlet needle assembly.
Fig. 30
7. Remove pilot jet (
A
) with Screwdriver #
19062
.
8. Pry off the idle mixture valve limiter (
B
), if
used. Remove the idle mixture screw and
spring ([
C
] Fig. 31).
Fig. 31
9. Remove screws (
A
) holding choke pl ate
([
B
] Fig. 32) and remove.
Fig. 32
10. Lift out choke shaft (
A
) with upper (
B
)
and lower ([C] Fig. 33) choke shaft
bushings.