13.2 MDR-508xx-1000
For mounting centre holes please refer to MDR-BKT-01 drawing.
Bracket Position
MDR height from ground
1 (highest on bracket)
30 mm
2
28 mm
3
14 mm
4 (lowest on bracket)
6 mm
14 Appendices
14.1 Video Quality Table
Using Brigade’s Resource calculator, the below tables have been compiled. Please note the following:
➢
The values below are for reference only
➢
Streaming bandwidth can vary considerably according to the level of variations in the image. Static images are more efficiently
compressed than dynamic ones
➢
Frame rates are assumed to be set to maximum which is 25fps for PAL and 30fps for NTSC
Quality level
1 (Highest)
2
3
4
5
6
7
8 (Lowest)
Video Streaming Data
Rate (Kbps) depending
on resolution
D1
2048
1536
1230
1024
900
800
720
640
HD1
1280
960
768
640
560
500
450
400
CIF (Lowest)
800
600
480
400
350
312
280
250
14.2 Normal / Alarm Recording Parameters
Warning: The values shown below are for reference only.
The table below summarises typical recording sizes for 1 channel at different qualities and resolutions for one-hour durations:
Quality level
1
(Highest)
2
3
4
5
6
7
8
(Lowest)
Recording data size (MB
per hour) depending on
resolution
D1 (Highest)
900
675
540
450
395
351
316
281
HD1
562
422
337
281
246
219
198
176
CIF (Lowest)
351
264
211
176
153
137
123
110
The following table is valid for both the
MDR-504xx-500
using all
4
channels and
MDR-508xx-1000
using all
8
channels. It illustrates
approximate
HDD
recording times in hours:
Quality level
1 (Highest)
2
3
4
5
6
7
8 (Lowest)
fps
Recording Time onto
HDD (hours) depending
on resolution
D1 (Highest)
142
160
231
299
367
425
481
539
12 (8CH)
25 (4CH)
HD1
170
211
272
340
408
466
522
580
25
CIF (Lowest)
199
326
435
544
652
746
837
932
25
Summary of Contents for MDR-504-500
Page 9: ...9 3 5 MDR 504xx 500 Connection Diagram MDR 504xx 500 Connection Diagram Figure 8...
Page 10: ...10 3 6 MDR 508xx 1000 Connection Diagram MDR 508xx 1000 Connection Diagram Figure 9...
Page 89: ...89...
Page 90: ...90...
Page 91: ...91...
Page 92: ...92 18 10 2017 10 52 00 MDR 500 Series Installation Operation Guide v2 0 ENG 5145A docx...