— 34 —
BRIG
The inflatable tube of the boat has five independent air-tight chambers. Before inflation it's necessary to set all valves in operating condition.
In order to switch valve in operating condition, please press spindle 6 (Fig. D3) with your finger and rotate it clockwise until the spindle
will be fixed. If this operation isn't possible, it means the valve already has been set in operating condition.
Fill the tube with air using the pump from the complete set. First fill two rear chambers, next two middle chambers. However, do not increase
the pressure up to its operating value (the tube will be completely straightened). After that, please fill the fore chamber up to the rated
pressure.
The rated pressure value is 0.2 bar (2.9 psi).
Having completed filling, close the valve covers.
In order to discharge air from the tube chambers, open the valves (please press spindle 6 (Fig. D3) with your finger and rotate it
anticlockwise until the spindle will be fixed).
INFLATION/DEFLATION OF THE BOAT TUBE.
Board air chambers are hermetical if they keep own form during 8 hours. In this case:
– primary pressure has to be nominal;
– input valves openings have to be tightly closed by caps.
The rated pressure value is 0.2 bar (2.9 psi).
If the tube pressure more than nominal, deflate the tube slightly. Boat exploitation with board pressure
more than nominal decreases boat service life.
Do not use compressors and/or other types of inflating equipments not approved by the boat builder.
Check the tube pressure before every navigation.