![BREL brel-motors DC-425 Manual Download Page 1](http://html1.mh-extra.com/html/brel/brel-motors-dc-425/brel-motors-dc-425_manual_2807058001.webp)
Page 1
BREL motors is part of:
Manual Brel radio signal amplifier
Type DC-425
Read the manual before you start the installation. If this instruction is not followed, you can
this leads to damage where no claim can be made on the guarantee.
Warning:
Children can not recognize the dangers of this electrical equipment and may therefore not work with it.
It is important to carefully follow this manual for your own safety.
____________________________________________________________________________________
Button specifications
Up
P2
Mode
Channel-
Time
Down
Operates with these BREL motors and transmitters:
Motors:
MR, MEV, MCE, MDE, MLE, MJE, MTE, MEQ, MPE.
Transmitters: DC-50, DC-90, DC-92, DC-94, DC-101, DC-109, DC-114, DC-227, DC-252, DC-253, DC-292, DC-305, DC-306, DC-2702.
______________________________________________________________________________
Technical data of the amplifier
Type DC-425
Voltage motor:
220V
Power:
900 Watt
Ampèrage
4 A
Moisture and dust resistance:
IP44
Storage capacity of channels is up to 20 channels
Working temperature:
o
Normal use: -10
℃
tot +40
℃
o
Heavy use:
-20
℃
tot +70
℃
____________________________________________________________________________
Functions of the amplifier
Reach
L1 = 100 meter
L2 = 25 meter
When all de LED lights burn for
the DC-306 or for the DC-313
channel 0, all products are
then active. (mode and time
have only a function on a
emitter with a timer)