9.2
Maintenance intervals
The practical maintenance intervals can only be determined by the user since
they depend on the operating conditions, for instance:
•
type and temperature of the cleaning solution,
•
ambient conditions.
Maintenance intervals
Applications
Maintenance intervals
(guideline values)
Inspection
175 hours of operation
Maintenance
500 hours of operation
9.3
Disassembly
9.3.1
Remove the lower body
Prerequisite:
•
The cleaner must be removed, cooled and completely emptied.
Unscrew the nozzle support
Perform the following steps:
1.
Insert the pin punch (SP 1) through the opening in the bottom of the lower
body.
Fig.12
2.
Move the nozzle support: Rotate the drive shaft (18) gap in the opening to
move the nozzle support until the pin punch (SP 1) blocks movement.
Maintenance
Maintenance intervals
430BAL011762EN_2
28.05.2018
35