![Braun A5S1-n Series Manual Download Page 33](http://html.mh-extra.com/html/braun/a5s1-n-series/a5s1-n-series_manual_2802450033.webp)
A5S1-n-Manual_EN_Rev02 2021_JAN_19
Page 33 of 36
4
Technical Specifications
4.1
Conformity to Standards
EU-Directive(s)
Standard(s)
2014/34/EU
ATEX product directive
EN IEC 60079-0
EN IEC 60079-15
2014/30/EU
EMC directive
EN 61326-1, EN IEC 61326-3-2
2014/35/EU Low voltage directive
EN 61010-1
2011/65/EU
RoHS directive
EN IEC 63000
4.2
Power Supply
Supply voltage: + 6
V… + 30 V DC.
Max. supply current: see certificates from chapter 2.3.
For use in zone 2: see certificates from chapter 2.3.
The sensors of the A5S1...-n series may only be operated in hazardous area zone 2.
Current consumption: approx. 15 mA (one channel sensor) resp. 25 mA (two channel sensor),
plus load (can increase up to 60 mA with long transmission length and high signal frequency).
If powe
r supply isn’t provi
ded by a BRAUN device, a PELV resp. SELV power supply has to be
used.
4.3
Signal Output
Rectangular pulses with constant high level and low level over the entire speed range
.
Push-Pull amplified output. Maximum load 20 mA.
The signal output is short circuit proof and protected against polarity error.
4.4
Speed (Frequency-) Range
Speeds with a maximum signal frequency of:
A5S1DS
…
-n:
0 Hz…12 kHz
A5S1DD
…
-n:
0 Hz…25 kHz
4.5
Signal Transmission
Cable in shielded version LiYCY with 3x0.5 mm
2
, resp. 4x0.5 mm
2
with R < 36 Ohm/km and C <
150 pF/m).
4.6
Electrical Protective Measures
Protection class: no protection needed
IP code:
IP67, pressure-tight stainless-steel housing (1.4305)
4.7
Connection
Connection with screw-plug-in connection (straight or angled) or with fixed PVC (up to 85°C) or
Teflon® (up to 125°C) cable.
4.8
Permissible Ambient Temperature
See certificates from chapter 2.3.
4.9
Installation Dimensions
The sensors are available with different installation threads (D) metric, resp. inch, resp. inch with
NPT, and each with a number of different nominal lengths (L). This is the length from the front
surface of the sensor to the end of the mounting thread (see figures on chapter 7).