Page 16
Troubleshooting Diagnosis Chart
1.00
NO
OPERATION
2.11 Hydraulic Down valve open
2.12 Pump mounted horizontal
2.13 No oil (low)
1.11 Low battery
1.12 Bad ground
1.13 Poor plug connections
1.14 Blown fuse
1.15 Circuit Sentry
1.16 Defective Interlock
Check vehicle battery
Check for good ground between vehicle chassis
and 3/8” bolt on back of power pack.
Check all plugs for proper contact.
Check fuses on P.C. board.
Reset circuit breaker.
Check for voltage on gray wire with red stripes in
interlock plug connected to P.C. board.
FUNCTION
POSSIBLE CAUSE
REMEDY
2.00
PUMP RUNS
BUT WILL
NOT LIFT
PLATFORM
Flush valve by operating Up and Down manual
override switches at same time for 4 to 5 seconds
several times.
Power pack must be mounted vertically.
Use Braun 87010R (5606 aviation
fl
uid). Do
not mix with Dextron III or other hydraulic
fl
uids.
Check
fl
uid level with platform lowered fully. Fill to
maximum
fl
uid level indicated on reservoir (speci-
fi
ed on decal). Do not over
fi
ll. If
fl
uid level decal
is not present - measure 7/8" from the bottom of
fi
ll
tube to locate
fl
uid level.
3.11 Up Solenoid
3.12 Bad power and ground
3.00
PUMP DOES
NOT RUN WITH
OVERRIDE
SWITCH OR
HAND-HELD
PENDANT
Check for power on pump black wire going from
solenoid to motor.
See 1.00
Troubleshooting and
repair procedures
must be performed
as speci
fi
ed by au-
thorized service per-
sonnel only. Failure
to do so may result
in serious bodily
injury and/or property
damage.
If a problem occurs with your
lift, discontinue operation imme-
diately! Do not attempt repairs
yourself. Contact your dealer or
call The Braun Corporation. One
of our national Product Support
representatives will direct you to
an authorized service repairman
who will inspect your lift.
The cause of the problem can
be determined by locating the lift
function and related symptom in
the Troubleshooting Diagnosis
Charts. The speci
fi
c cause and
remedy can then be determined
by process of elimination. A Wir-
ing Schematic, Hydraulic Dia-
gram and Hydraulic Schematic
are provided to aid in trouble-
shooting.
A Repair Parts section with ex-
ploded views and corresponding
parts lists is also provided. Cor-
rect the problem if possible. If the
problem continues, contact The
Braun Corporation.
WARNING