WARNING:
DO NOT stretch the connector to
make it fit.
Connector must be long enough to
allow the appliance to be positioned at its farthest
anticipated connected distance from the gas supply
without stretching, twisting or bending smaller that a
1-1/2 internal diameter (diameter of a golf ball).
WARNING:
DO NOT trap connector against sharp
edges or corners.
CAUTION: DO NOT kink, twist or bend connector sharply.
6.
Turn manual shut-off valve on to allow gas to enter system.
WARNING:
DO NOT TURN ON APPLIANCE
until all
connections have been leak tested!
WARNING:
DO NOT USE
matches, candles, open
flames or other sources of ignition to leak test
connections!
7. Test all connections with leak test solution provided,
or with clear soap and water solution; bubbles will
indicate a leak. If a leak is detected, turn off gas
supply before further tightening connections. Water
rinse and towel dry connector once test is complete.
8. Wait at least 10 minutes to be certain that all vapors
have dissipated. If leak test confirms connections do
not leak gas, and you do not smell any gas,
THEN light pilot(s) and turn on appliance.
Tools Needed for Installation:
• (2) 10 in. adjustable wrenches
• Pipe dope or gas pipe thread tape
• Leak detection solution
X
©2009, 2019 Brasscraft Manufacturing Company
325.01 Rev. 11/19
Brasscraft Manufacturing Co., 39600 Orchard Hill Place Novi, Michigan 48375-5331
TOLL-FREE: 877.272.7755 FAX: 248.305.6011 www.brasscraft.com
Manufacturer assumes no responsibility for failure due to improper installation.
©2019 Brasscraft Manufacturing Company, Novi, MI 48375-5331 U.S.A.
All Rights Reserved. www.brasscraft.com BrassCraft
®
brand is a trademark of Brasscraft Mfg. Co.
El fabricante no asume ninguna responsabilidad si la instalación no se hace de acuerdo al instructivo.
BrassCraft
®
brand es una marca registrada de Brasscraft Mfg. Co.
Gas Connector Maximum Flow Capacity
Part #
ID
Color Code
12
in
18
in
24
in
30
in
36
in
48
in
60
in
72
in
Gas Connector with Standard Fittings
CSSL
1/4
BTU’s
48,000
43,800
40,000
36,400
33,400
28,300
24,900
23,100
Purple
Watts
14,067
12,837
11,723
10,668
9,789
8,294
7,297
6,770
CSSD
3/8
BTU’s 102,000
93,100
85,000
77,100
71,100
60,500
53,200
49,100
Green
Watts
29,893
27,285
24,911
22,596
20,837
17,731
15,591
14,390
CSSC
1/2
BTU’s 180,000
164,200
150,000
136,000
125,000
106,000
93,200
86,000
Gold
Watts
52,752
48,122
43,961
39,858
36,634
31,066
27,314
25,204
Plus® (Gas Connector with Excess Flow Valve Attached)
CSSL
1/4
BTU’s
42,000*
37,400*
36,800*
36,400
33,400
28,300
24,900
23,100
Purple
Watts
12,308*
10,960*
10,784*
10,668
9,789
8,294
7,297
6,770
CSSD
3/8
BTU’s 102,000
93,100
85,000
77,100
71,100
60,500
53,200
49,100
Green
Watts
29,893
27,285
24,911
22,596
20,837
17,731
15,591
14,390
CSSC
1/2
BTU’s
122,000* 118,000* 115,000* 111,000* 107,000*
106,000
93,200
86,000
Gold
Watts
35,754*
34,581*
33,702*
32,530*
31,358*
31,066
27,314
25,204
*Note:
Connecting the safety valve lowers these values below the Z21.24/CSA 6.10 and Z21.75/CSA 6.27 standards
Listings & Certifications:
Components CSA listed to ANSI Z21.24 / CSA 6.10 standard “Connectors for
Gas Appliances”
Components CSA listed to ANSI Z21.75 / CSA 6.27 standard “Connectors for
Outdoor Gas Appliances & Manufactured Homes”
NOTE:
This connector meets or exceeds the minimum allowable capacity
as determined under test conditions specified in ANSI Z21.24 • CSA 6.10.
Straight length capacity rated in BTU per hr. using: 0.64 SP. Gr., 1000 BTU per
Cu Ft. Gas at 0.50 inch Water Column Pressure Drop. The capacity at 50 Pa
(0.2 inch water column) pressure drop can be determined by multiplying the
BTU per hr. listed in the table above by 0.632
.