0
Note:
If the instrument is not going to be used for a long
period, remove the batteries from the compartment!
When the battery voltage is too low a symbol will ap-
pear on the MIC 10 display:
If this symbol appears, the batteries must be immedi-
ately changed. The MIC 10 automatically switches off
if the batteries are too low in order to guarantee re-
liable measurement.
When measurements are made at remote locations a
spare set of batteries should be present.
Further information with regard to batteries and accu-
mulators can be found in Chapter 8.1.
0
Note:
Used or defective batteries are special refuse and
must be disposed of according to the governing laws!
3.2 Connection of hand-held probes
In order to prepare the MIC 10 for operation, the probe
must be connected. The probes available for the
MIC 10 are: MIC 201-A (1 kgf), MIC 205-A (5 kgf) and
MIC 2010-A (10 kgf).
–
Connect the probe to the probe cable. The red mark-
ing points at probe socket and cable connector
must be on top of each other.
–
Connect the probe cable to the MIC 10 socket.
–
Place the probe grip onto the probe.
–
Screw on the conical probe attachment for short
measurements (refer to Chapter 2.2
Required ac-
cessories
).
socket for
probe connection
Connection of hand-held probes
Preparations for operation
Krautkrämer MIC 10
Issue 08, 08/01
3-3
0
Note:
If the instrument is not going to be used for a long
period, remove the batteries from the compartment!
When the battery voltage is too low a symbol will ap-
pear on the MIC 10 display:
If this symbol appears, the batteries must be immedi-
ately changed. The MIC 10 automatically switches off
if the batteries are too low in order to guarantee re-
liable measurement.
When measurements are made at remote locations a
spare set of batteries should be present.
Further information with regard to batteries and accu-
mulators can be found in Chapter 8.1.
0
Note:
Used or defective batteries are special refuse and
must be disposed of according to the governing laws!
3.2 Connection of hand-held probes
In order to prepare the MIC 10 for operation, the probe
must be connected. The probes available for the
MIC 10 are: MIC 201-A (1 kgf), MIC 205-A (5 kgf) and
MIC 2010-A (10 kgf).
–
Connect the probe to the probe cable. The red mark-
ing points at probe socket and cable connector
must be on top of each other.
–
Connect the probe cable to the MIC 10 socket.
–
Place the probe grip onto the probe.
–
Screw on the conical probe attachment for short
measurements (refer to Chapter 2.2
Required ac-
cessories
).
socket for
probe connection
Connection of hand-held probes
Preparations for operation
Krautkrämer MIC 10
Issue 08, 08/01
3-3
Summary of Contents for Krautkramer MIC 10
Page 6: ...0 6 Issue 08 08 01 Krautkrämer MIC 10 ...
Page 7: ...1 Introduction Krautkrämer MIC 10 Issue 08 08 01 1 1 1 Introduction ...
Page 16: ...1 10 Issue 08 08 01 Krautkrämer MIC 10 ...
Page 29: ...4 Basics of operation Krautkrämer MIC 10 Issue 08 08 01 4 1 4 Basics of operation ...
Page 37: ...5 Operation Krautkrämer MIC 10 Issue 08 08 01 5 1 5 Operation ...
Page 69: ......
Page 70: ......
Page 71: ...6 Configuration Krautkrämer MIC 10 Issue 08 08 01 6 1 6 Configuration ...
Page 88: ...7 10 Issue 08 08 01 Krautkrämer MIC 10 ...
Page 89: ...8 Care and maintenance Krautkrämer MIC 10 Issue 08 08 01 8 1 8 Care and maintenance ...
Page 97: ...10 Specifications Krautkrämer MIC 10 Issue 08 08 01 10 1 10 Specifications ...
Page 100: ...10 4 Issue 08 08 01 Krautkrämer MIC 10 ...
Page 123: ...12 Appendix Krautkrämer MIC 10 Issue 08 08 01 12 1 12 Appendix ...
Page 133: ...13 Changes Krautkrämer MIC 10 Issue 08 08 01 13 1 13 Changes ...
Page 135: ...14 Index Krautkrämer MIC 10 Issue 08 08 01 14 1 14 Index ...