Electrical Connections
6-8
Digital Compact
6.2.6
Select Switches for Additional Functions
The following functions can be set using the DIP switches or the soft-
ware:
•
Seek
Options for control, monitoring and storage of the operating
frequency.
•
Amplitude control
Enables changing the amplitude (50% to 100%) via external control
or maintaining a fixed value respectively.
•
Reference times for the ramp start
Control function for the start by selection of ramp times to reduce
stress on the components of the acoustic stack.
Access:
1. Disconnect the module from mains supply.
DANGER!
HIGH VOLTAGE! Contact with live parts causes electrocution.
Disconnect mains supply.
Wait 5 minutes before opening the unit for capacitors to
discharge.
2. Remove the screws of the lower cover (perforated plate).
3. Set the DIP switches as desired.
4. Install the cover and connect the module.
Fig. 6-2
DIP switches
STOP
ON
OFF
DIP switch towards number = OFF
DIP switch away from number = ON
Summary of Contents for DC 222
Page 2: ......
Page 42: ...Description of the Unit 4 14 Digital Compact...