Chapter 2: Introduction to the 2000X ao Actuator
Instruction Manual
Glossary of Terms
Calibrate Sensors:
The ability to calibrate the reported pressure sensor and force against an out-
side standard.
Calibrate Standards:
The menu title for accessing the calibration and verification of pressure,
force, power, and energy.
Cold Start:
A condition that restores a setup to its default values.
Collapse Cutoff:
Ends the ultrasonic portion of the cycle when the set parameter is reached.
Collapse Distance:
The distance the horn has travelled from the trigger point of ultrasonics.
Collapse Mode:
A mode in which the ultrasonics portion of the cycle is terminated when a user-
specified distance from the trigger point has been reached.
Control Limits:
Additional parameters that determine the end of the ultrasonic portion of the
cycle and the move to the hold state.
Converter:
The device that converts electrical energy into mechanical vibrations at a high fre-
quency (an ultrasonic rate). The Converter is a central component of the welding system and is
mounted in the Actuator.
Counters:
A record of the number of cycles run by category, for example, alarms, good parts,
and so on, recorded in the Controls.
Cycle Aborts:
Settings that end the cycle immediately.
Digital Filter:
A smoothing technique used to provide more meaningful data.
Down Speed:
The user-definable speed of descent (percentage of maximum speed) during the
down stroke of the Actuator.
Energy Mode:
A mode of operation in which ultrasonics are terminated at a user-specified
energy value.
External Amplitude Control:
Enables you to access real-time amplitude control directly.
External Frequency Control:
Enables you to access real-time frequency control directly.
Force A:
The force applied to the part from the start of the weld to the step change.
Force B:
The force applied to the part from the step change to the end of the weld.
Force Step:
A change of force during the cycle.
Form Feed:
When using a printer with the 2000Xd Power Supply to capture weld data, you can
insert a form feed after print setup, print graph, or after reaching the number of lines per page.
Frequency:
The operating frequency of the ultrasonic stack. The frequency stored is measured
at the end of the ultrasonic portion of the cycle (when ultrasonics are terminated).
Freq End:
The frequency at the end of the ultrasonic portion of the welding cycle (when ultra-
sonics are terminated).
F Actual:
The actual running frequency of the acoustic system.
F Memory:
The frequency stored in the Power Supply memory.
Frequency Offset:
An offset factor applied to the ultrasonic frequency stored in the Power
Supply.
Summary of Contents for 2000X ao
Page 2: ......
Page 8: ...iv 100 214 281 Rev 07 ...
Page 10: ...vi 100 214 281 Rev 07 ...
Page 12: ...viii 100 214 281 Rev 07 ...
Page 44: ...3 4 100 214 281 Rev 07 Chapter 3 Delivery and Handling Returning Equipment ...
Page 84: ...4 40 100 214 281 Rev 07 Chapter 4 Installation and Setup Still Need Help ...
Page 90: ...5 6 100 214 281 Rev 07 Chapter 5 Technical Specifications Physical Description ...