Brandywine FDU-240 User Manual Download Page 1

 

 
 

MANUAL P/N 900000035 REV C 

 
 
 
 
 
 
 

User Guide 

 

Frequency Distribution Amplifier 

 

Model FDU-240 

 

P/N 022000001 

 
 

Revision C 

 

March 2006 

 
 
 
 
 
 
 
 
 
 
 
 

Brandywine Communications 

1153 Warner Avenue 

Tustin, CA 92780 

(714) 755 1050 
(714) 755 0175 

 

http://www.brandywinecomm.com/ 

 

Summary of Contents for FDU-240

Page 1: ...35 REV C User Guide Frequency Distribution Amplifier Model FDU 240 P N 022000001 Revision C March 2006 Brandywine Communications 1153 Warner Avenue Tustin CA 92780 714 755 1050 714 755 0175 http www b...

Page 2: ...ory REVISION DATE COMMENTS NC 07 14 2004 Original release of FDU 240 user guide A 09 08 2004 Revision of entire FDU 240 user guide B 02 21 2006 Customer s comments incorporated into FDU 240 user guide...

Page 3: ...uilateral triangle is intended to alert the user to the presence of un insulated dangerous voltage within the product s enclosure The dangerous voltage may be of sufficient magnitude to constitute as...

Page 4: ...ches and Indicators 7 1 3 1 Status LED Indicators 7 1 3 2 Environmental 7 1 3 3 Power 7 1 3 4 Physical 7 2 Option Configuration Sheet 8 3 Unpacking and Installation 9 3 1 Unpacking 9 3 2 Installation...

Page 5: ...ut Impedance 50 ohm Number of Inputs 2 with auto selection and manual override from the front panel toggle switch Connector Type BNC 1 1 2 Fault Discrete Optional Number of Inputs 2 Level TTL Link sel...

Page 6: ...z o 5 MHz Output Level 13 2 dBm standard and specified at time of order Stability o With External Reference Only Same as reference o With Free Running Internal Oscillator Stability vs Temperature 3 x...

Page 7: ...Green Reference Input B Available Green Reference Input B Online Green Automatic Reference Selection Selected Green Fault Red 1 3 2 Environmental Temperature o Operating 30 to 60 C o Storage 40 to 85...

Page 8: ...UND PIN 8 GROUND PIN 9 NO CONN ACTIVE H__Lb ACTIVE H__Lb b REFERENCE A INPUT 1 0 Vrms b J3 FREQUENCY 10 MHz REFERENCE A SOURCE EXTERNAL _____b_____ FREE RUNNING OCXO ____________ OCXO PHASE LOCKED TO...

Page 9: ...D FROM THE FDU 240 BEFORE ADJUSTING THE LINE VOLTAGE If the AC line setting is incorrect detach the power cord from the power entry module Use a small screwdriver to lift up the fuse cover on the powe...

Page 10: ...ions GPS8 or PTS system that incorporates a discrete alarm signal This alarm signal is used to indicate a fault e g rubidium out of lock on the reference signal although the 10 MHz input signals may b...

Page 11: ...tial warm up of the frequency reference The FDU 240 is now ready for operation 4 2 Selecting the Input Reference The external reference frequency used is selected by the Reference Select Switch 3 Movi...

Page 12: ...ource 1 Connect the reference input 2 Select an internal source 3 Return to factory for repair Fault light illuminated 1 There is an internal OCXO failure 2 There is a failed output driver 3 There is...

Page 13: ...ze 4 Connect one of the 10 MHz reference outputs to a frequency counter with at least an 11 digit resolution CAUTION The frequency counter MUST be configured to use an external reference such as a Ces...

Page 14: ...MANUAL P N 900000035 REV C 14 7 Drawings FIGURE DESCRIPTION 1 FDU 240 Front Panel 2 FDU 240 Rear Panel 3 FDU 240 Mechanical Outline 4 FDU 240 Link Location...

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ...PRODUCT QUALITY How would you rate our product High quality Generally good Quality varies Poor quality How would you rate our user guide High quality Generally good Quality varies Poor quality What pr...

Reviews: