5
220-240 V
∼∼
50 Hz
Total energy consumption
:
TV321.....5,6 kW
TV323.....6,6 kW
Installing your hob in complete safety
C
onnection
You must use a 32
Amp fuse on your ins-
tallation
You must use a 16
Amp fuse on your ins-
tallation
1
2
3
4
L1
L2
N
1
2
3
4
L1
N
Your hob must be connected to the mains with:
- A H05RRF type cable with three 2.5 mm² conduc-
tors or five 1.5 mm² conductors (including a yellow /
green earth wire)
- A plug that complies to CEI 60 083
recommendations or an all-pole circuit breaker with
contacts that open by at least 3 mm.
When the power is switched on, or after a long power failure, a light
code appears on the control panel. This disappears automatically after
about 30 seconds or as soon as any touch control is touched on the
panel. This is normal, as the display is for use by the after-sales service when required. The user must not
take this into account under any circumstances.If the unit has a 3 phase 400 V2N connection, and is not
working correctly, check that the neutral wire is correctly connected. This precaution should also be taken
for all your other electronic apparatus.
"When installing the hob, precautions must be taken to avoid damaging the power cable with the sharp
edges"
L1
N
4
3
2
1
220-240V
400V2N
Summary of Contents for TV321BT1
Page 32: ...32 BRANDT BRANDT Brandt BRANDT Brandt BRANDT 33 34 35 36 37 38 39 39 40 41...
Page 33: ...33...
Page 37: ...37 H 0 0 3 4 3 4 H 2 1 4 8 5 7 2 8 9 1 1 9...
Page 38: ...38 0 0 99mn 0...
Page 39: ...39 0 3 E E...
Page 40: ...40...
Page 41: ...41 I TH ANI MA I 9 8 7 6 5 4 3 2 1 9 2 1...
Page 42: ...42...
Page 43: ...43...
Page 44: ......