background image

Gas Hob 

Installation and Operator's Manual

Semi-fast 

burner

Auxiliary 

burner

Fast

burner

Double crown 

burner

Summary of Contents for TE217FS1

Page 1: ...Gas Hob Installation and Operator s Manual Semi fast burner Auxiliary burner Fast burner Double crown burner...

Page 2: ...4 GAS CONNECTION P 5 HOW TO MAKE THE CHANGE OF GAS TYPE FOR THE COOKING HOB P 6 7 GAS RATING P 11 COOKING GUIDE P 12 PART 2 FOR THE USER HOW TO USE THE GAS BURNERS P 8 WHICH SAUCEPANS TO USE ON THE G...

Page 3: ...d the combustion products must be evacuated a minimum air input of 2 m3 hour per kw of gas energy is required These hobs are in accordance with the cup boards overheating tests of the standards EN 603...

Page 4: ...xternal rim of the carter This joint ensures sealing between the cooking hob and the work surface 3 Place the cooking hob in the opening of the support unit taking care to centre it well in the cut ou...

Page 5: ...not exceed 2 metres in length and their entire length must be accessible For the user s safety we advise the connection to be made with a rigid pipe if this is possible or with a rein forced braided...

Page 6: ...ector Screw them right in without forcing With a pencil draw a line on the hearth plate as indicated fig 3 Turn the spanner clockwise until the line appears on the other side fig 4 Remount the heads c...

Page 7: ...ob to maximum position remove the knob of the corresponding tap using the screwdriver unscrew the yellow brass adjustment screw fig 5 turning it round twice anti clockwise put back the knob and turn i...

Page 8: ...o or r r r t t t th h h he e e e U U U Us s s se e e er r r r 8 NOTA If the flame is accidentally extinguished just re light it normally following the ignition instructions Your hob is equipped with...

Page 9: ...sing a gas cooking appliance produces heat and humidity in the room in which it is installed Your kitchen should be well ventilated Keep all natural vents open or install a mechanical ventilation devi...

Page 10: ...hest position for 3 to 5 seconds until the gas reaches the burners Light the burner by placing the knob between maximum and minimum gas flow Check that the injectors fitted correspond to the gas being...

Page 11: ...nal heat rating kW 3 65 3 21 3 8 Low heat rating kW 1 900 1 500 Fast burner Indicator marked on injector 78 78 121 Nominal heat rating kW 2 30 2 02 2 40 Low heat rating kW 0 830 0 870 Semi fast burner...

Page 12: ...EGETABLES ENDIVES SPINACH X X PEAS IN SAUCE 25 30 MINUTES X X PROVENCE TOMATOES 15 20 MINUTES X X FRIED POTATOES X X PASTA X X MEAT STEACK X X BLANQUETTE OSSO BUCCO 90 MINUTES X FRIED ESCALOPE 10 12 M...