11. Display 

11.1 Main Rotation 

11.1.1 MAIN ROTATION FOOTER 

Reference

: When PTP Mode is selected in the reference menu, the display in the Main Rotation pages indicates REF: PTP on 

the left of the reference line with 4 different options to its right: 

-

“Master: External” 

-

“Master: Internal” 

-

“Master: Internal / OCXO” 

-

“Master: GPS Receiver” 

As explained in 3.1 above, selecting PTP Mode in the reference menu means 
that the DXD-8 will participate in the PTP Grandmaster selection (see 12.5, 
Selecting a Grandmaster). If another unit is selected by the BMCA, “Master: 
External” will be displayed in the reference line. 

But, if the DXD-8 is selected, one of the other 3 options above will be 
displayed: Internal, Internal / OCXO or GPS Receiver. 

Lock Status

: The bottom line of the display has the usual LOCK status, but in the case where the DXD-8 is the grandmaster, 

when locked it changes to "LOCKED / GRANDMASTER”. 

In case the DXD is or becomes a PTP Salve, when locked it changes to “LOCKED / PTP SLAVE”.  

Note that, if another source was selected in the reference menu, such as Video Sync, and the DXD-8 was simultaneously a PTP 
Grandmaster, the same LOCK status would appear, but the REF line would indicate “REF: Input A/ Vid” (see example at 15.1). 

11.1.2 MAIN ROTATION PAGES 

The Main Rotation Pages are the pages appearing on the main display under normal operations when the DXD is neither in the 
Status nor the Set Up mode. With the installation of the PTP and/or GPS options, some pages have been modified, others have 
been added. 

•REFERENCE SOURCES - PTP Mode 

When PTP Mode is selected in the reference menu, the Reference 
Sources page indicates the setting and the state of the PTP port in colors 
for easy identification as well as the PTP domain to its right. For details 
on the PTP states, see Chapter 11, PTP Ports States. 

If GPS is available and has been selected in the reference menu as 
‘LOCAL REF WHEN GM’, it will appear on the second section in place of 
the ALT REF along with its lock status. 

Summary of Contents for DXD/GPS

Page 1: ...k DXD OCXO OCXO option for the DXD Universal Clock Operations manual Version 2 10 January 2021 All materials herein Brainstorm Electronics Inc Brainstorm Electronics reserves the right to change or mo...

Page 2: ...6 GPS Menus 8 6 1 SATELLITES SELECTION MENU 6 1 8 6 2 GPS SETTINGS MENU 6 2 8 6 3 ADVANCED GPS SETTINGS MENU 6 3 8 7 DXD OCXO 9 8 Time of Day 9 8 1 RTC Real Time Clock 10 8 2 Time Jam 10 8 2 1 TIME JA...

Page 3: ...9 15 Typical PTP use 20 15 1 HYBRID SYNC GENERATOR ACCEPTING MULTIPLE REFERENCES 20 15 2 DISTRIBUTED PTP VS INDIVIDUAL GRANDMASTERS WITH GNSS 21 16 Guidelines for con fi guring PTP Precision Time Prot...

Page 4: ...a series of 4 numbers separated by periods This key is only valid for the DXD 8 with the serial number used when you placed the order Note that PTP is optional on the DXD 8 only A feature key is not r...

Page 5: ...ng LOCAL REF WHEN GM When PTP Mode is selected if GPS is available this fields enables GPS to be set as the reference when the DXD 8 is the Grandmaster Enabling this field will announce the DXD 8 as G...

Page 6: ...a quick set up This menu gives you the option to set the timing values to the pro fi le default values 4 4 PORT TIMING MENU 5 4 Announce Interval 3 to 4 1 8sec 16sec Sets the rate at which the master...

Page 7: ...in your DXD an antenna will need to be connected to the receiver s SMA connector an antenna is not included with the DXD GPS The cable needs an SMA Male connector on the DXD side Ideally the antenna s...

Page 8: ...sideration as it can not only impact the signal strength but also cause a delay in the signal Under typical conditions however the expected cable delay is negligible in the nanoseconds range The follo...

Page 9: ...e reference sources include time and rate information GPS and PTP for example carry precise time and date information as well as frequency However traditional reference signals such as video sync or w...

Page 10: ...nd wanting all of the cross frame outputs 25 etc to be in correct phase and epoch as well as wordclocks and AES In a primarily legacy application this is the way to increase the number of legacy outpu...

Page 11: ...to use Local Time instead while others may even prefer different standards for different times Be aware that even though the time source may give Time Of Day it may not correspond to the time indicate...

Page 12: ...on Jan 1 1970 This process occurs everyday at the same time as set in the DAILY JAM TIME fi eld Daily Jam Time The value entered in the DAILY JAM TIME field is the amount of time after midnight local...

Page 13: ...to LOCKED GRANDMASTER In case the DXD is or becomes a PTP Salve when locked it changes to LOCKED PTP SLAVE Note that if another source was selected in the reference menu such as Video Sync and the DXD...

Page 14: ...lock and the Grandmaster in sec Additional times may appear on this page such as Time Code based on the installed options 11 2 2 GPS RECEIVER STATUS PAGE The GPS RECEIVER status page displays the foll...

Page 15: ...as the ability to clock to a non Dante PTP v2 clock AVB Audio Video Bridging is a set of IEEE standards that facilitate the transport of high performance audio and video on a LAN One of those standard...

Page 16: ...suited clock is found it will become the Grandmaster 12 6 SYNCHRONIZATION There are several different PTP messages used during synchronization sequenced as follows 1 The grandmaster sends a Sync messa...

Page 17: ...clocks on a single PTP communication path must use the same method to measure the time delay 12 8 TYPES OF CLOCKS IEEE 1588 de fi nes three different types of clocks Ordinary Clock OC Boundary Clock...

Page 18: ...ate of the port can change The BMCA determines what unit becomes the Grandmaster If the current Grandmaster disappears or looses GPS another Grandmaster is selected For more on the Grandmaster selecti...

Page 19: ...it has been set by the operator 14 1 JUMP TO RELOCK When the time difference detected between the external PTP GM and the DXD System Time is above the Jump Threshold value the DXD will jump to the ne...

Page 20: ...t all equipment could be kept perfectly synchronized But for added fl exibility the DXD s can also be set up to lock to any legacy sync or to PTP as illustrated below These choices are available in th...

Page 21: ...TP slaves to an external Grandmaster in the second illustration the DXD 8 s are all Grandmaster for their networks and each is locked to GNSS This second solution is particularly useful when distances...

Page 22: ...ith any other domain number will be ignored menu 5 2 Ports Timing per IEEE 1588 all devices on a PTP domain must have the same value set for these ports timing Announce Interval Announce Receipt Timeo...

Page 23: ...GMPv2 On larger networks a router is required to manage multicast group membership Switches that support IGMP snooping are also recommended 17 Troubleshooting Error Warning Messages 17 1 PTP NO PORT W...

Page 24: ...3 Menu 5 1 If PTP was selected TIME JAM BNC INPUT will automatically show in menu 5 1 in blue blue status information The words Time Jam will also appear on the REFERENCE line at the bottom of the ma...

Page 25: ...the ribbon cable to J23 the GPS connector on the motherboard B J23 is the designator number on both DXD 8 and DXD 16 PCB As always with ribbon cables make sure the connectors are properly oriented do...

Page 26: ...Including cable loss Low Gain mode FLNA High 3 For best jammer resistance and lower power consumption use 10 dB lower gain than the max gain 18 3 2 RECOMMENDED PASSIVE ANTENNA 1 High Gain mode FLNA Op...

Page 27: ...TIMEOUT 3 announce intervals SYNC INTERVAL 1 sec log 0 MINIMUM DELAY REQUEST INTERVAL 1 sync interval GLONASS Yes GALLILEO No QZSS LIC A Yes SBAS QZSS LIS SBAS DIF FIX ANTENNA CABLE DELAY 0 ANTENNA H...