BL-IL-60960-34EN Rev2.0
*60960-34EN*
Converter Kit DVI to S-Video
19179
ENGLISH
Intended Use
The
Converter Kit
is intended to be used by surgeons or other
clinical personnel in OR environment during image guided
surgery (IGS) for integration of video signals from video sources
with only DVI-output to navigation platforms without DVI-IN
interfaces.
Overview
No.
Component
①
S-Video OUT
②
Mains Power Connector
③
Ports for Video and Audio Output
④
HDMI Video IN
⑤
USB (for service purposes only)
⑥
Power Supply Connector
Power LED Status
Color
Status
Explanation
Blue
Off
No power connection, electronic
components are off
Solid
Connection to mains power,
electronic components are on
Compatibility
Only use the
Converter Kit
with Brainlab navigation systems:
Kick
Curve
Only use compatible C-arms.
For a complete compatibility list, contact Brainlab support.
Brainlab accepts no liability if unapproved scanners or C-arms
are used.
Video Connections
Port
Example
Handling
S-Video
OUT
Connect the
Converter Kit
to
the
Brainlab
navigation
system with an S-Video cable
to interact
with
Brainlab
software video.
HDMI
IN
Connect
the
DVI
video
source to the
Converter Kit
with a DVI to HMDI cable.
NOTE: Use a high quality
HDMI cable to connect a
HDMI source.
Do not place the Converter Kit in the patient environment.
Additional equipment connected to medical electrical
equipment must comply with the respective IEC or ISO
standards (e.g. IEC 60950 for data processing equipment
and IEC 60601-1 for medical equipment). Furthermore, all
configurations shall comply with the requirements for
medical electrical systems (see IEC 60601-1-1 or clause 16
of the 3rd edition of IEC 60601-1, respectively). Anyone
connecting the Converter Kit to medical electrical
equipment configures a medical electrical system and is
therefore responsible that the system complies with the
requirements for medical electrical systems. Please note
that local laws take priority over the above-mentioned
requirements. If in doubt, consult your local representative
or the technical service department.
NOTE: Unless otherwise specified, the use of multiple socket
outlet(s) is not permitted.
Startup Test
Perform a functional test before first use at each day of use. To
do this, the
Converter Kit
must be connected to the video
source and the Brainlab navigation System as described above.
Verify that the image shown on the Brainlab navigation system
is correct.
Cleaning the Converter Kit
The
Converter Kit
can be cleaned with disinfectants containing
-
Alcohol 50%/60%, e.g. Meliseptol
-
Alkylamine 0,7% (in 2% solution), e.g. Incidin Plus 2%
-
Active Oxygen 1,35% (in 3% solution), e.g. Perform
-
Aldehyde 1% (in 4% solution)
-
Chloride 0,4% (in 4% solution)
How to clean the
Converter Kit
1.
Shut down the system by unplugging the mains power.
2.
For cleaning and disinfection, use a moist cloth and
clean all surfaces using a surface disinfectant. Follow the
disinfectant manufacturer’s recommendations.
3.
Carefully clean interfaces, ensuring that no liquids enter
the system.
4.
For cleaning of all other devices refer to the respective
Instruction for Use.
Storing the Converter Kit
Use the delivered transportation bag to store or transport the
Converter Kit
.
How to store Converter Kit
1.
Unplug the mains power and disconnect all video cables.
2.
Clean the
Converter Kit
and put it into the transportation
bag.
3.
Coil up each cable and put them into the transportation
bag.
Trouble Shooting
Problem
Possible Cause
No Power
Check that the mains power cabling is
correctly connected to power supply.
No Image
Check that all video cables are correctly
connected.
Expected Service Life
Brainlab provides a minimum of eight years of service for