Magnet rack - disassembly, step by step
There are two main reasons for disassembling the magnet
rack. It could be to replace some parts, i.e. defect magnet or
worn pivot arm, or it could be for regular maintenance.
The magnet racks can be considered as the part of the printer
that will have the greatest influence on the dot quality, so it is
very important to know how to deal with them.
Take the magnet rack out of the printer like described in section
5.5 ‘Magnet rack - removal’ on page
.
Next, follow the instructions below.
Step 1.
Remove the two nuts holding the support list, and then remove the support list.
Support list