Braeburn 140424 Installer'S Manual Download Page 9

Transformer Wiring

 

3.3

 

24V
24C

C

C

HOT

Dedicated

Zoning Transformer

Zone

Panel

Zone Addressing

 

4

 

Use the following instructions to identify the zones on the zone panel expander. 
No other configuration is necessary on the zone panel expander. Carefully slide 
the dip switches to match the new zone numbers. 

Use the open area provided on the expander panel to mark the new zone 
numbers. When setting the switches to identify the expander panel, use a pen 
or small screwdriver. Do not use a pencil, which may contain conductive material 
in the writing point.

 

 

               

Switch Position

Zone ID              1 

 2 

  3 

   4

5 and 6 

OFF 

OFF 

OFF 

OFF

7 and 8 

ON 

OFF 

OFF 

OFF

9 and 10 

OFF 

ON 

OFF 

OFF

11 and 12 

OFF 

OFF 

ON 

OFF

13 and 14 

OFF 

OFF 

OFF 

ON

15 and 16 

ON 

ON 

OFF 

OFF

17 and 18 

ON 

OFF 

ON 

OFF

19 and 20 

ON 

OFF 

OFF 

ON

21 and 22 

OFF 

ON 

ON 

OFF

23 and 24 

OFF 

ON 

OFF 

ON

25 and 26 

OFF 

OFF 

ON 

ON

27 and 28 

ON 

ON 

OFF 

OFF

29 and 30 

ON 

ON 

OFF 

ON

31 and 32 

ON 

OFF 

ON 

ON

9

O

N

1     2     3     4

Install the transformer using the instructions provided by the manufacturer. Size 
the transformer to the damper requirements. The zone panel has a built-in, self-
resetting fuse. The maximum damper power per zone is 75 VA at 24 VAC. Connect 
the transformer to the zone panel as shown. 

NOTE:

  

Additional dampers or 

dampers with a higher current draw will require the use of a separate slave relay.

ALWAYS PROVIDE DISCONNECT AND OVERLOAD PROTECTION AS REQUIRED

Example Switch Position 

for Zones 15 and 16

Summary of Contents for 140424

Page 1: ...ing for the main panel and expansion panel before applying transformer power This panel is designed for professional installation and is to be installed and configured as described in this manual Any...

Page 2: ...tronic self resetting current limiting for panel power and damper zones Configuration Zone number by switch setting Maximum Zones 2 Zones Per Expander Panel Up to a Maximum of 14 Two Zone Expanders 32...

Page 3: ...all stud roof truss or the return air plenum For appearance mount the panel near the main panel for easy panel to panel wiring Remove the panel cover and use the base as a template to drill mounting h...

Page 4: ...l wiring instructions for all systems Specific wiring will vary depending on the type of thermostats and dampers used for the installation NOTE Up to 2 wires can be inserted into each terminal positio...

Page 5: ...MPERS PO 2 OUTPUT 24 VAC Power Open Zone Damper Terminal C 2 OUTPUT Zone Damper Common Terminal PC 2 OUTPUT 24 VAC Power Close Zone Damper Terminal EXPANSION COM1 2 OUTPUT Expander Panel Communication...

Page 6: ...Zones Located Remote to Main Panel Remote Panels Wired in Star Configuration 6 Main Panel Expander Panel Zones 5 6 Expander Panel Zones 7 8 Expander Panel As Needed Daisy Chain All Zones Located at Ma...

Page 7: ...Damper PO C PC PO COM PC Zone Panel 3 Wire Damper 7 Thermostat Wiring 3 2 1 HEAT 1 COOL R 24 VAC Power W1 Heat Call Y1 Cooling Call G Fan Call C 24 VAC Transformer Common Note 1 2 HEAT 2 COOL R 24 VAC...

Page 8: ...ll G Fan Call C 24 VAC Transformer Common Note 1 3 HEAT 2 COOL With Auxiliary Heat R 24 VAC Power O B Changeover Valve Note 2 L Optional System Fault Monitor AX1 Auxiliary Heat Relay 3rd Stage Heating...

Page 9: ...ON OFF OFF OFF 9 and 10 OFF ON OFF OFF 11 and 12 OFF OFF ON OFF 13 and 14 OFF OFF OFF ON 15 and 16 ON ON OFF OFF 17 and 18 ON OFF ON OFF 19 and 20 ON OFF OFF ON 21 and 22 OFF ON ON OFF 23 and 24 OFF...

Page 10: ...ar check wiring and ensure expansion zones have power 5 Press HOLD FOR EXIT for 3 seconds to complete adding zones Operation 6 The Zone Panel Expander has built in LED s to tell the installer and the...

Page 11: ...the communication terminals To locate the expander panel with the invalid address view the expander panel status LED The status LED will be flashing red Duplicate Address on Expansion Panel Displayed...

Page 12: ...opy of this warranty Visit us online www braeburnonline com warranty Phone us 866 268 5599 Write us Braeburn Systems LLC 2215 Cornell Avenue Montgomery IL 60538 5YEAR WARRANTY LIMITED Braeburn Systems...

Reviews: