Bradyprinter THT X-Plus II Series User Guide
Data Ports
Standard Ports
Serial Port
To communicate using the serial data port of the printer, you must choose the number
of data and stop bits, parity, and handshaking. Parity applies only to data transmitted
by the printer because the parity of received data is ignored.
The values selected must be the same as those used by the host equipment connected
to the printer. Default settings are 9600 baud, 8 data bits, 1 stop bit, no parity, and
XON/XOFF.
Connect the serial data cable to the female DB-9 connector (shown below) on the back
panel of the printer.
Use a DB-9 to DB-25 interface module for all RS-232 connections through a DB-25
cable. An interface module is required for RS-422/RS-485 interface support
(see
RS-422/RS-485 Interconnections
Note •
For all RS-232 input and output signals, the printer follows the specifications
of the Electronics Industries Association (EIA) RS-232 and the Consultative
Committee for International Telegraph and Telephone (CCITT) V.24.
Summary of Contents for Bradyprinter THT 300X-PLUS
Page 1: ...Bradyprinter THT 300X Plus II 360X Plus II 600X Plus II...
Page 10: ...viii Bradyprinter THT X Plus II Series User Guide...
Page 28: ...xxvi Bradyprinter THT X Plus II Series User Guide Preface Related Documents...
Page 36: ...8 Bradyprinter THT X Plus II Series User Guide Introduction Printer Components...
Page 48: ...20 Bradyprinter THT X Plus II Series User Guide Getting Started Ribbon...
Page 82: ...54 Bradyprinter THT X Plus II Series User Guide Print Modes Remove Backing from Rewind Spindle...
Page 128: ...100 Bradyprinter THT X Plus II Series User Guide Front Panel Controls Front Panel LCD...
Page 156: ...128 Bradyprinter THT X Plus II Series User Guide Troubleshooting Printer Diagnostics...
Page 179: ......