LVSD2
Installation
2
9/1/2022
Bradley
• 215-1829 Rev. E: ECO 22-08-005
Safety Information
WARNING
Make sure that all water supply lines have been flushed and then completely turned off before beginning
installation. Debris in supply lines can cause valves to malfunction.
Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation. Electrical
power MUST remain off until installation is complete.
Installer's hardware must be appropriate for wall construction. Wall anchors must have a minimum pull-out
rating of 1,000 pounds.
IMPORTANT
Read this entire installation manual to ensure proper installation. When finished with the installation, file this
manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances
is the responsibility of the installer. Product warranties may be found under “Products” on our Website at
www.bradleycorp.com.
Separate parts from packaging and make sure all parts are accounted for before discarding any packaging
material. If any parts are missing, do not begin installation until you obtain the missing parts.
For standard height mounting, do not exceed the recommended 33.5" distance from the fixture rim to the
finished floor.
Supplies Required
• (6)
³⁄₈
" fasteners and wall anchors for bowl and wall bracket (minimum pull-out rating of 1,000 lb)
• (2) ¼" fasteners and wall anchors for access panel brackets (minimum pull-out rating of 100 lb)
• ½" hot/cold or tempered stub-out
• 1½" NPT drain stub-out(s)
• OPTIONAL: (2) 110V GFCI protected electrical outlets for 100–120VAC plug-in transformers only
• OPTIONAL: (2)
³⁄₈
" NPS x
³⁄₈
" NPT Male Adapter for IR-DCD faucet only
• Screen filter(s) as needed, if not included with faucet(s)
• Drill
• Crescent wrench
• Tape measure
• Phillips screw driver
• Flat head screw driver
• Level