Bradley Terreon Quadra-Fount MF2949/IR Installation Manual Download Page 1

Installation

MF2949/IR

Terreon

®

 Quadra-Fount

™ 

Wall-

Hung Washfountain with Adaptive 
Infrared Control

(Standard*, Juvenile* and OBC Height)

* Standard and Juvenile Height are ADA/TAS Compliant

IMPORTANT!

Read this entire installation manual to ensure proper installation. When 

finished with the installation, file this manual with the owner or maintenance 

department.

Separate parts from packaging and make sure all parts are accounted for 

before discarding any packaging material. If any parts are missing, do not 

begin installation until you obtain the missing parts.

Water supply requires a flowing pressure of at least 20 psi, but no greater 
than 80 psi. 

Make sure that all water supply lines have been flushed and then completely 
turned off before beginning installation. Debris in supply lines can cause 
valves to malfunction.

Hardware supplied by installer must be appropriate for wall construction. Wall 

anchors used must have a minimum pull-out rating of 1,000 lbs.

The adaptive infrared control must be connected with a 24 VAC Class II 

transformer. Connections to 110 VAC can cause personal injury and will result 

in damage to the electronics.

Product warranties may be found under “Product Information” on our web site 

at www.bradleycorp.com.

THIS

SIDE

UP

Packing List

Installation

Table of Contents

Pre-Installation Information   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Parts Included with the Quadra-Fount

 .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

Installation Instructions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .4-8
Cleaning and Maintenance   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .9-10
Troubleshooting .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .11-12

215-1249 Rev. R; ECN 14-00-006
© 2014 Bradley
Page 1 of 12 

6/5/2014

P .O . Box 309, Menomonee Falls, WI  53052-0309
Phone: 1-800-BRADLEY  Fax: (262) 251-5817
http:\\www .bradleycorp .com

Summary of Contents for Terreon Quadra-Fount MF2949/IR

Page 1: ...en completely turned off before beginning installation Debris in supply lines can cause valves to malfunction Hardware supplied by installer must be appropriate for wall construction Wall anchors used...

Page 2: ...dirt The sensor is accessible by removing the top cover All electrical components are housed within the pedestal Solenoid valve An electronically controlled solenoid valve serves as the metering mecha...

Page 3: ...repack TL S45 2731 optional Stop Hose Solenoid Assembly with Two Mounting Screws Parts included with the Wall Hung Quadra Fount Separate all parts from packaging materials and ensure you have all the...

Page 4: ...Installer to Mount Bowl to Wall 26 1 4 667 23 584 110V GFI Electrical Outlet Recommended Location Refer To Local Codes Before Rough In 1 2 Nominal Copper Tubing for Hot Supply Stub Out 1 2 1 4 57 25...

Page 5: ...rews F For optional single tempered supply attach the stop to the 1 2 tempered supply line Connect the stop to the solenoid valve assembly with the flexible supply hose 1 4 20 x 1 2 Screws Solenoid Va...

Page 6: ...bolts and washers supplied by installer G Fasten the bowl to the upper bracket on the pedestal frame with the two 1 4 20 x 1 2 round head screws and 5 16 I D washers supplied H Install the drain spud...

Page 7: ...p the transformer circuit plug into the female transformer circuit plug located on the valve bracket C Insert four different colored sprayhead supply tubes into four solenoid tube connectors by loosen...

Page 8: ...er temperature is reached Do not turn past stops as this may damage unit Push cover down and tighten screw 7 Install Top Cover and Front Panel A Carefully place the top cover with threaded rods on top...

Page 9: ...recommends additional care and maintenance for the darker colored Terreon For complete instructions on this additional maintenance see Bradley document 1505 Do not use strong acid or alkaline chemica...

Page 10: ...oducts leave a protective coating that helps prevent future smears and fingerprints Grease and Oil To remove grease and oil use a quality commercial detergent or caustic cleaner Apply in accordance to...

Page 11: ...ion to determine the cause 1 Disconnect the wires from the coil of an adjacent valve Disconnect the wires from the problem valve and reconnect to the adjacent valve 2 Turn on electrical and water supp...

Page 12: ...ter temperature or temperature fluctuation Hot water supply is not 10 above desired set point Increase hot water supply temperature Valve temperature is not properly set Adjust the temperature as show...