Bradley Terreon Multi-Fount Series Installation Instructions Manual Download Page 7

Terreon® Quadra-Fount™ Wall-Hung Washfountain with Adaptive Infrared Control

Installation Instructions

MF2949/IR

7

Bradley Corporation • 215-1249 Rev. H; EN 03-045

9-15-2003

Installation Instructions continued . . . 

Step 6: Assemble and install bowl

1. Install two 3/8" wall anchors (supplied by installer). These will be used to mount the bowl to the

wall.

WARNING:  Do not attempt to install the bowl by yourself. To prevent injury, install

the bowl with the assistance of another person and always use
appropriate lifting procedures.

2. With the help of an an assistant, carefully lift the bowl on the pedestal frame using appropriate

lifting procedures. Ensure bowl remains 3 - 4 inches from the wall.

WARNING: Do not leave the bowl on the pedestal unsupported, as it may fall and

cause personal injury or damage to property.

3. Install the 2 wall anchor brackets to the back of the bowl using the 3/8-16 x 2" hex head bolts,

13/32" I.D. plain washers, anchor plates, lockwashers and hex nuts provided (see Figure 5).

4. Uncoil the infrared sensor leads and plastic tubing from the rear of the backsplash.

5. Slide the bowl back to the wall and secure the bowl’s wall brackets to the wall anchors with two

3/8" diameter bolts and washers (supplied by installer).

6. Fasten the front underside of the bowl to the upper bracket on the pedestal frame with the two

1/4-20 x 1/2" round head screws and 5/16" I.D. washers supplied.

7. Install the drain spud in the bowl using plumber’s putty (see Figure 6).

NOTE: Discard rubber gasket included with drain spud. It cannot be used in this application.

8. From beneath bowl, thread the washer and locknut onto the drain spud and tighten the locknut

against the bowl.

9. Install strainer in the bowl drain using the two #10-24 x 1/2" oval Phillips head screws supplied.

Back View of Washfountain Bowl

Figure 6

Spud

Washer

#10-24 x 1/2"
Screw for
Strainer

Drain

Spud

Dome

Strainer

Discard this
washer; it is not
used on
washfountains.

Washfountain
Bowl

Spud

Locknut

Drain Assembly

Figure 5

Summary of Contents for Terreon Multi-Fount Series

Page 1: ...f 13 9 15 2003 P O Box 309 Menomonee Falls WI 53052 0309 TEL 1 800 BRADLEY FAX 262 251 5817 http www bradleycorp com IMPORTANT Read through this installation manual to ensure proper installation Make...

Page 2: ...itutional purchaser and does not extend to any others including consumer customers of commercial institutional purchasers 6 This warranty is in lieu of all other warranties expressed or implied includ...

Page 3: ...d waste connection Pipe sealant and plumber s putty 110 VAC power source for 110 24 VAC plug in transformer supplied OPTIONAL Bradley recommends installing an electrical cut off switch to the unit Thi...

Page 4: ...l frame assembly IMPORTANT Make sure that the water is completely shut off before beginning installation 1 Rough in hot and cold supply lines through the wall 2 Rough in a drain waste connection throu...

Page 5: ...ps 1 4 nuts and washers provided 3 Connect the 1 2 NPT female end of the stop check valves to the rough ins 5 Insert the filter washers provided into the swivel nut at the end of the supply hoses 6 Co...

Page 6: ...assembly on the exposed portion of the screws Connect Flexible Hose at this end Solenoid Assembly Pedestal Frame 1 4 20 x 5 8 Screws Figure 3 Step 5 Install pedestal panels 1 Install three 1 4 20 x 1...

Page 7: ...ex head bolts 13 32 I D plain washers anchor plates lockwashers and hex nuts provided see Figure 5 4 Uncoil the infrared sensor leads and plastic tubing from the rear of the backsplash 5 Slide the bow...

Page 8: ...es into four solenoid tube connectors by loosening the tube connector cap and firmly pushing tubing into tube connector until the tubes are fully seated then re tighten connector cap see Figure 7 IMPO...

Page 9: ...the main water supply to the Quadra Fount and check for leaking 3 Pass your hand in front of each sensor until air is purged from the lines Step 9 Install top cover 1 Install the threaded rods into t...

Page 10: ...3 8 screw supplied through the welded nut on the bottom flange of the access panel see Figure 9 DO NOT tighten 2 Position the access panel by sliding the screw into the bracket slot on the pedestal f...

Page 11: ...Terreon Solid Surface material Bradley recommends additional care and maintenance for the darker colored Terreon for complete instructions on this additional maintenance see Bradley document 1505 IMP...

Page 12: ...e manufactures instructions Many of these products leave a protective coating the helps prevent future smears and fingerprints Grease and Oil To remove grease and oil use a quality commercial detergen...

Page 13: ...ke sure both orifices are open 5 Reassemble in reverse order Do not overtighten the bonnet nut or you may crack the plastic valve body Hand tight plus 1 8 turn is sufficient 6 Reconnect the wiring per...

Reviews: