Cleaning and Maintenance Instructions for Terreon®

Material Description: Terreon

® 

is a NAHB Certified densified solid surface material composed of polyester

resin and is resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with
everyday cleansers or fine grit abrasives.

Routine Cleaning: Clean daily or as often as conditions require using a standard commercial or household
cleaner such as Formula 409

®

or Windex

®

.

Stubborn Stains: Remove tough stains with Ajax

®

, Comet

®

, or Soft-Scrub

®

and a green Scotch-Brite

®

pad or

lightly sand in a circular motion with 240 grit wet/dry sandpaper. The finish can be renewed with a maroon
Scotch-Brite pad.

Special Situations for Material

Scratches: Remove scratches with a green Scotch-Brite

®

pad. The finish can then be renewed with a maroon

Scotch-Brite

®

pad.

Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. Always rinse
the unit thoroughly after cleaning.
Restoring the surface: Use Hope's

®

Solid Surface cleaner and polish to refresh and protect the Terreon

Solid Surface material.Bradley recommends additional care and maintenance for the darker colored Terreon,
for complete instructions on this additional maintenance see Bradley document #1505.

IMPORTANT:

DO NOT USE STRONG ACID OR ALKALINE CHEMICALS AND
CLEANSERS TO CLEAN TERREON. IF THESE CHEMICALS COME IN
CONTACT WITH THE TERREON SURFACE, WIPE THEM OFF
IMMEDIATELY AND RINSE WITH SOAPY WATER.

AVOID CONTACT WITH HARSH CHEMICALS SUCH AS PAINT REMOVER,
BLEACH, ACETONE, ETC. AVOID CONTACT WITH HOT PANS AND
OBJECTS.

Repair Kits: Terreon

®

repair kits are available. Contact your Bradley representative or distributor for part

numbers and pricing.

NOTE: Repair kits are made to order and have a shelf life of 30 days.

Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an
endorsement, or does the omission of any brand name cleaner imply it’s inadequacy. Many products named are
regional in distribution, and can be found in local supermarkets, department and hardware stores, or through
your cleaning service. It is emphasized that all products should be used in strict accordance with package
instructions.

NOTE: When cleaning units equipped with infrared (electronic eye) activation, it is helpful to turn
off the power to the unit or cover the windows to prevent accidental activation. After the window is
covered, the water will run for approximately 30 seconds and then shut off.

Summary of Contents for Terreon Multi-Fount Series

Page 1: ...f 13 9 15 2003 P O Box 309 Menomonee Falls WI 53052 0309 TEL 1 800 BRADLEY FAX 262 251 5817 http www bradleycorp com IMPORTANT Read through this installation manual to ensure proper installation Make...

Page 2: ...itutional purchaser and does not extend to any others including consumer customers of commercial institutional purchasers 6 This warranty is in lieu of all other warranties expressed or implied includ...

Page 3: ...d waste connection Pipe sealant and plumber s putty 110 VAC power source for 110 24 VAC plug in transformer supplied OPTIONAL Bradley recommends installing an electrical cut off switch to the unit Thi...

Page 4: ...l frame assembly IMPORTANT Make sure that the water is completely shut off before beginning installation 1 Rough in hot and cold supply lines through the wall 2 Rough in a drain waste connection throu...

Page 5: ...ps 1 4 nuts and washers provided 3 Connect the 1 2 NPT female end of the stop check valves to the rough ins 5 Insert the filter washers provided into the swivel nut at the end of the supply hoses 6 Co...

Page 6: ...assembly on the exposed portion of the screws Connect Flexible Hose at this end Solenoid Assembly Pedestal Frame 1 4 20 x 5 8 Screws Figure 3 Step 5 Install pedestal panels 1 Install three 1 4 20 x 1...

Page 7: ...ex head bolts 13 32 I D plain washers anchor plates lockwashers and hex nuts provided see Figure 5 4 Uncoil the infrared sensor leads and plastic tubing from the rear of the backsplash 5 Slide the bow...

Page 8: ...es into four solenoid tube connectors by loosening the tube connector cap and firmly pushing tubing into tube connector until the tubes are fully seated then re tighten connector cap see Figure 7 IMPO...

Page 9: ...the main water supply to the Quadra Fount and check for leaking 3 Pass your hand in front of each sensor until air is purged from the lines Step 9 Install top cover 1 Install the threaded rods into t...

Page 10: ...3 8 screw supplied through the welded nut on the bottom flange of the access panel see Figure 9 DO NOT tighten 2 Position the access panel by sliding the screw into the bracket slot on the pedestal f...

Page 11: ...Terreon Solid Surface material Bradley recommends additional care and maintenance for the darker colored Terreon for complete instructions on this additional maintenance see Bradley document 1505 IMP...

Page 12: ...e manufactures instructions Many of these products leave a protective coating the helps prevent future smears and fingerprints Grease and Oil To remove grease and oil use a quality commercial detergen...

Page 13: ...ke sure both orifices are open 5 Reassemble in reverse order Do not overtighten the bonnet nut or you may crack the plastic valve body Hand tight plus 1 8 turn is sufficient 6 Reconnect the wiring per...

Reviews: