Wall-Hung Washfountain
with Adaptive Infrared
Control

(Standard* & Juvenile Height)

*ADA compliant when mounted at recommended
heights

Installation
Instructions

Table of Contents

Pre-Installation Information  . . . . . . . . . . . . . . . . . . . .2
Washfountain Component Parts  . . . . . . . . . . . . . . . . .3
Installation Instructions . . . . . . . . . . . . . . . . . . . . .4-10
Cleaning Instructions . . . . . . . . . . . . . . . . . . . . . .11-12
Solenoid Valve Troubleshooting  . . . . . . . . . . . . . . .13

215-1249 Rev. H; EN 03-045
© 2003 Bradley Corporation 
Page 1 of 13

9-15-2003

P.O. Box 309, Menomonee Falls, WI 53052-0309
TEL. 1-800-BRADLEY

FAX  262-251-5817

http://www.bradleycorp.com

IMPORTANT

Read through this installation manual to
ensure proper installation.

Make sure that water supply is completely
off before installation is begun.

When drilling into tile, masonry, or other
hard materials to install wall and floor
anchors, be sure to wear safety goggles
to prevent eye injuries.

Wall anchors used must have a minimum
pull-out rating of 1,000 lbs.

The Quadra-Fount™ requires a water
flowing pressure of at least 20 psi but no
greater than 100 psi.

File these instructions with the owner or
maintenance department.

Summary of Contents for Terreon Multi-Fount Series

Page 1: ...f 13 9 15 2003 P O Box 309 Menomonee Falls WI 53052 0309 TEL 1 800 BRADLEY FAX 262 251 5817 http www bradleycorp com IMPORTANT Read through this installation manual to ensure proper installation Make...

Page 2: ...itutional purchaser and does not extend to any others including consumer customers of commercial institutional purchasers 6 This warranty is in lieu of all other warranties expressed or implied includ...

Page 3: ...d waste connection Pipe sealant and plumber s putty 110 VAC power source for 110 24 VAC plug in transformer supplied OPTIONAL Bradley recommends installing an electrical cut off switch to the unit Thi...

Page 4: ...l frame assembly IMPORTANT Make sure that the water is completely shut off before beginning installation 1 Rough in hot and cold supply lines through the wall 2 Rough in a drain waste connection throu...

Page 5: ...ps 1 4 nuts and washers provided 3 Connect the 1 2 NPT female end of the stop check valves to the rough ins 5 Insert the filter washers provided into the swivel nut at the end of the supply hoses 6 Co...

Page 6: ...assembly on the exposed portion of the screws Connect Flexible Hose at this end Solenoid Assembly Pedestal Frame 1 4 20 x 5 8 Screws Figure 3 Step 5 Install pedestal panels 1 Install three 1 4 20 x 1...

Page 7: ...ex head bolts 13 32 I D plain washers anchor plates lockwashers and hex nuts provided see Figure 5 4 Uncoil the infrared sensor leads and plastic tubing from the rear of the backsplash 5 Slide the bow...

Page 8: ...es into four solenoid tube connectors by loosening the tube connector cap and firmly pushing tubing into tube connector until the tubes are fully seated then re tighten connector cap see Figure 7 IMPO...

Page 9: ...the main water supply to the Quadra Fount and check for leaking 3 Pass your hand in front of each sensor until air is purged from the lines Step 9 Install top cover 1 Install the threaded rods into t...

Page 10: ...3 8 screw supplied through the welded nut on the bottom flange of the access panel see Figure 9 DO NOT tighten 2 Position the access panel by sliding the screw into the bracket slot on the pedestal f...

Page 11: ...Terreon Solid Surface material Bradley recommends additional care and maintenance for the darker colored Terreon for complete instructions on this additional maintenance see Bradley document 1505 IMP...

Page 12: ...e manufactures instructions Many of these products leave a protective coating the helps prevent future smears and fingerprints Grease and Oil To remove grease and oil use a quality commercial detergen...

Page 13: ...ke sure both orifices are open 5 Reassemble in reverse order Do not overtighten the bonnet nut or you may crack the plastic valve body Hand tight plus 1 8 turn is sufficient 6 Reconnect the wiring per...

Reviews: