Installation
SN2008/IR
Bradley Corporation
• 215-1069 Rev. G; EN 10-00-015
7-12-2010
5
1
Install and Anchor Unit
Rough-in of plumbing lines must be completed before unit
can be properly installed.
2
Connect Water Supply to Valve Assembly
Hot Supply Inlet
Cold Supply Inlet
Vernatherm TMV
Braided
Hose
Stop/Check Valve
A
Connect 1/2" NPT female end of stop/check
valves to supply lines. Connect supply hoses
to hot and cold inlets of the Vernatherm TMV.
B
OPTIONAL TEMPERED LINE CONNECTION: Connect 1/2" NPT
female end of stop/check valve to supply line. Connect Tempered
line adapter to Gang Valve Assembly as shown.
Do not turn on water
until Step 3 is completed!
A
Remove Access panel and with
the help of another person, place
unit in position.
C
Install a minimum of four 3/8" bolts (supplied
by installer) around unit at the marked
locations (eight is recommended). Secure
unit to fl oor.
B
Ensure unit is level, shimming fl oor unit if
necessary. Using the base as a template,
mark the fl oor anchor locations.