Installation
SN2008/IR
Bradley Corporation
• 215-1069 Rev. G; EN 10-00-015
7-12-2010
3
Supplies required for installation:
• 3/8" diameter bolts and floor/wall anchors to anchor washfountain pedestal to floor and wall
• 1/2" hot and cold water supply lines and fittings
• 1/2" nom. copper tubing supply lines for types with supplies from above
• Standard P-trap (trap included with “B” or “H” drain type and some optional equipment)
• 1-1/2" drain lines and fittings
• Pipe sealant
Supplies recommended for installation:
• 1-1/2" vent or tie pipe on types vented through washfountain column
• Caulk (may be applied between backsplash and bowl to avoid debris accumulation)
• Electrical cut-off switch to the unit. This feature prevents accidental water delivery during regular maintenance and service.
Dimensions - Sentry
™
54" Circular Washfountain
(mm)
40-1/4" (1022)
36-3/4" (920)
33" (838)
39" (736)
29" (737)
25" (635)
43" (1092)
39" (990)
54" (1372)
15-1/2"
(394)
18-1/2"
(470)
Juvenile Height dimensions, where
different, are shown in Italics.
Standard height fl oor-mounted models
with Infrared or hand control are ADA
compliant.