background image

5

Installation 

S19-788H

Bradley Corporation • 215-1416 Rev. P; ECN 12-05-001C 

4/3/2012

Fill tank and pressurize

NOTICE: DO NOT open the cover until the pressure gauge reads “0.”

1.  Open the tank by pulling up on the wire handle located on top of the Quick-lock cover. Push down, rotate and remove. Make sure that 

the interior of the container is clean. Fill the container with 12 gallons of tepid potable water. 

2.  Replace the cover and secure by pulling up on the cover and down on the wire handle.
3.  After filling the tank with tepid water and before pressurizing the unit, open the activation valve to the full open position and remove the 

dust covers from the eyewash heads. 

4.  Located beneath the pressure gauge is an air valve. Remove protective cover and begin to pressurize the unit by applying pressured 

air through the valve. As soon as water begins discharging from the eyewash, close the activation lever completely. Finish pressurizing 

the tank to 90 psi and replace the air valves protective cover.

If this is the initial startup of this unit or if the unit has been unfilled and/or un-pressurized for a prolonged 

period of time the unit should be flushed out per the procedure below.

Prior to placing unit in service let unit stand for one hour.  If there is a noticeable pressure drop, re-pressurize 

and let stand for an additional hour.  If unit continues to exhibit pressure loss DO NOT place unit in service and 

consult the Troubleshooting guide found on page 6 of this manual.

CAUTION:  Relief valve is designed to vent automatically at 100-130 psi to prevent the tank from over pressurizing.   

If the gauge ever reads more then 130 psi immediately open the pressure relief valve manually by pulling 

up on the relief valve tab until the pressure reads zero. Remove the unit from service and consult the 

troubleshooting guide found on page 6 in this manual for steps to correct the problem.  Return the unit to 

service only when over-pressurization issue is corrected.

Flush tank

1.  Be sure the unit is assembled, filled and pressurized according to Steps 1 & 3 above, (If this is the initial start up of the unit the body 

wash spray head will not be attached to the drench hose activation valve at this time.)

2.  Discharge the water through the eyewash for at least five minutes to flush the system.
3.  Flush all remaining fluid in the tank.
4.  Refill the tank and pressurize as described in Step 3 above.
5.  Inspect the electrical components for any visible damage or fraying. Plug the heater jacket’s electrical cord into an appropriate 

electrical outlet in accordance with state and local codes.

3

Filling the Tank

Maintenance

WARNING:   Follow instructions of the preservative manufacturer for the proper use of water preservative.

Inspect eyewash unit

1.  Visually inspect the pressure gauge weekly to ensure the unit is maintaining the proper pressure. If the unit is not working properly, 

remove it from the hazard area immediately and refer to the troubleshooting instructions. For further assistance, contact the Bradley 

Corporation.

Clean eyewash unit

 

When using potable water only:

1.  Empty the tank any time from once per week to once per month, depending on the quality of your water supply. The manufacturer 

is not responsible for variations in the water supply.

2.  Clean the inside of the tank using warm water and mild soap. Rinse the tank thoroughly with warm water. 
3.  Refill the eyewash tank with tepid potable water.

When using potable water and water preservative (recommended):

1.  Clean the inside of the tank using warm water and mild soap. Rinse the tank thoroughly with warm water. 
2.  Refill the eyewash tank with tepid potable water. Follow instructions of the preservative manufacturer for the proper use of water 

preservative.

Troubleshooting

1.  If pressure relief valve relieves prior to the required pressure, do the following (when in the unpressurized condition):

•  Tighten the valve completely into the cap by turning the gray hex head portion of the pressure relief valve clockwise. Do not use 

a wrench.

•  Pull up on the relief valve ring and ensure that the ring is not preventing the valve from closing completely. Push on the center 

pin of the relief valve to ensure that it is completely closed. Repressurize tank to required pressure. This may have to be done 

several times to get the valve to seat completely.

2.  If the pressurized tank loses pressure over time, check the connections with diluted liquid dish soap or children’s bubbles to identify 

the leak location. Tighten the connection slightly and test again.

Summary of Contents for S19-788H

Page 1: ...nsions 3 Eyewash Installation 3 Heater Jacket Installation 4 Filling the Tank 5 Maintenance Troubleshooting 5 Components Parts List 6 Table des mati res Avant l installation 7 Dimensions 8 Installatio...

Page 2: ...ormation may also be found under Products on our web site at www bradleycorp com Disconnect before servicing Inspect cord for fraying Make sure there is no visible damage to the yoke s electrical syst...

Page 3: ...o the tank Max torque 150 In Lbs Route the cable through the tank handle NOTICE Check to ensure the heat trace cable from the yoke assembly is not kinked or damaged from assembly A Attach the pressure...

Page 4: ...the jacket just to the side of the eyewash yoke away from the retaining spring on the heater pad Slide the jacket up the outside of the tank A Close the zipper on the pocket and lock closed with scre...

Page 5: ...the drench hose activation valve at this time 2 Discharge the water through the eyewash for at least five minutes to flush the system 3 Flush all remaining fluid in the tank 4 Refill the tank and pre...

Page 6: ...sket 1 22 269 1642 1 Relief Valve 1 3 269 1411 2 O Ring 1 4 269 1939 1 Draw Tube 1 5 269 1515 1 Level Indicator Tube 2 269 1970 1 Heater Jacket 3 153 451 1 Adapter 4 169 786 1 Pressure Gauge 5 S27 320...

Page 7: ...onform ment la norme ANSI Z358 1 Pour toute question concernant le fonctionnement ou l installation de ce produit consulter le site www bradleycorp com ou appeler le 1 800 BRADLEY Les garanties de pro...

Page 8: ...de sortie du r servoir Couple maximum 150 in lbs Passez le c ble dans la manette du r servoir AVIS Assurez vous que le c ble de douche oculaire n est pas endommag A Monter le manom tre l adaptateur a...

Page 9: ...ue de la ceinture chauffante directement sous la t te de douche oculaire V rifier l absence de toute salet sur la bande chauffante et le r servoir Installez la bande autour du r servoir 4 102mm de la...

Page 10: ...pareil en service le laisser au repos pendant une heure S il se produit une chute de pression notable le remettre sous pression et attendre une heure suppl mentaire Si l appareil continue de pr senter...

Page 11: ...mand s 1 Nettoyez l int rieur du r servoir en utilisant l eau chaude et un produit doux de savon Rincez le r servoir compl tement avec de l eau chaud 2 Refaire le plein du r servoir de douche oculaire...

Page 12: ...ube d aspiration 1 5 269 1515 1 Tube de niveau 2 269 1970 1 Chemise de chauffange 3 153 451 1 Adaptateur 4 169 786 1 Manom tre 5 S27 320 1 Valve de r servoir 6 261 011B 1 Bande chauffante 7 114 051 1...

Page 13: ...pueden encontrar e n Informaci n del producto o en nuestro sitio Web www bradleycorp com Desconecte antes de realizar mantenimiento Revise si existe desgaste en el cable Aseg rese de que no hayan da o...

Page 14: ...erzo de torsi n m ximo 150 in lbs Pase el cable a trav s del manija del tanque AVISO Aseg rese de que el cable del conjunto de la horquilla no est da ado A Adjuntar el man metro al adaptador en el lad...

Page 15: ...a Fije las regletas de gancho y bucle en la ranura del camisa calentadora Tire firmemente del cord n en la parte superior del camisa calentadora D Correa del calentador Camisa calentadora Alinee la ab...

Page 16: ...r por una hora Si hay una ca da de presi n evidente vuelva a presurizarla y d jela reposar por una hora m s Si la unidad sigue exhibiendo p rdida de presi n NO la ponga en servicio consulte la gu a de...

Page 17: ...ua potable y el preservativo del agua recomendados 1 Limpie el interior del tanque usando el agua caliente y un producto suave del jab n Aclare el tanque a conciencia con agua caliente 2 Vuelva a llen...

Page 18: ...269 1515 1 Tubo del indicator 2 269 1970 1 Camisa Calentadora 3 153 451 1 Adaptador 4 169 786 1 Manometro 5 S27 320 1 V lvula del tanque 6 261 011B 1 Correa del calentador 7 114 051 1 Letrero de segu...

Reviews: