Navigator

®

 Thermostatic Mixing 

Valve for Sinks/Faucets

Pre-Installation Information   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Supplies and Tools Required .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Troubleshooting  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Parts List   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

Inlet Connections: 1/2" NPT
Outlet Connection: 1/2" NPT
Temperature Range: 95 – 125°F 
Maximum Pressure: 125 PSIG
Inlet Temperature, Hot: 120 – 180°F
Inlet Temperature, Cold: 33 – 80°F
Minimum Temperature Differential (from valve set point): 10°F

®

ASSE 1070 & cUPC certified

215-1852 Rev. C; ECN 18-09-011
© 2018 Bradley
Page 1 of 4 

2/1/2018

Summary of Contents for Navigator S59-4007

Page 1: ...ation 2 Supplies and Tools Required 2 Installation 3 Troubleshooting 4 Parts List 4 Inlet Connections 1 2 NPT Outlet Connection 1 2 NPT Temperature Range 95 125 F Maximum Pressure 125 PSIG Inlet Temperature Hot 120 180 F Inlet Temperature Cold 33 80 F Minimum Temperature Differential from valve set point 10 F ASSE 1070 cUPC certified 215 1852 Rev C ECN 18 09 011 2018 Bradley Page 1 of 4 2 1 2018 ...

Page 2: ...and or unauthorized adjustments or repairs could render the valve ineffective for its intended service Frequency of cleaning and inspection depends upon local water conditions IMPORTANT Read this entire installation manual to ensure proper installation When finished with the installation file this manual with the owner or maintenance department Compliance and conformity to local codes and ordinanc...

Page 3: ...t Supply Lines 3 Adjust Temperature with Water Running A Loosen cap screw about 1 4 4 6 turns and lift up cover do not remove B Using cover turn cartridge gently until desired water temperature is reached Do not turn past stops as this may damage unit Push cover down and tighten screw 4 Test Unit 1 Assemble the Valve A Install check valves into valve assembly as shown in the Parts List Observe dir...

Page 4: ...per water temperature or temperature fluctuation Hot water supply is not 10 above desired set point Increase hot water supply temperature Valve temperature is not properly set Adjust the temperature as shown on page 3 step 2 Limited water flow Dirt and debris have built up in the valve or strainer 1 Check to make sure both hot and cold supplies are connected to the Navigator mixing valve and that ...