Lenox
®
Locker (includes Cubby & "Z" Lockers)
Installation
10 10/19/2017
Bradley •
LK-INSTR-001 Rev. N; ECN 17-13-005
Figure 7a
Figure 7b
WALL STRIP
1-1/4"
Optional Locker Slope Top Installation
7a
Standard 3-tier lockers are shown in Figures 7a–7e. Slope and
flat tops for Cubby and “Z" lockers are similar.
The slope tops are shipped in standard lengths and can be easily
modified during installation. This modification is often necessary
to overcome a variety of installation situations. Use a panel saw
to cut the slope top sections to the proper length if necessary.
Use the corner slope top in the corner as shown in Figure 7c on
page 10.
Corner slope tops should only be trimmed when they extend past
the edge of the locker.
Wall strips will be 54" maximum length. Color of wall strips may
vary.
1 . Drill the appropriate number of 3/16" dia . clearance holes
through the top of the installed lockers, making sure
that the holes are located 1-1/4" from the front edge of
the locker . This dimension is critical to ensure proper
installation (see Figure 7a) .
• Locker screw hole requirements: slope tops less
than 18" long, two holes; 18"–35" long, three
holes; 36"–45" long, four holes; 72" long, six holes .
2 . Position the wall strip (or strips) on top of the lockers
flush against the wall as shown in Figure 7b . Measure,
scribe and drill 1/4" mounting holes into the wall strip as
follows:
• CONCRETE/BLOCK WALLS: Start 1" from each
end and space holes equally (do not exceed 16"
on centers) . The holes must be located at least
1-1/4" from the bottom edge of the wall strip .
Use a 3/16" masonry drill bit and 1/4 x 1-3/4" Lg .
Tapcon screws to anchor the wall strip to the wall .
• STUD WALLS: Drill the mounting holes at every
stud location covered by the wall strip . The holes
must be located at least 1-1/4" from the bottom
edge of the wall strip . Anchor the wall strip to the
wall with #14 x 1-3/4" Lg . pan head screws .