GLX-2 / TLX-2
Installation
12
1/21/2021
Bradley
• 215-1901 Rev. C: ECO 20-08-028B
Mounting for Standard ADA and TAS height shown.
CODE
DESCRIPTION
QTY.
A
Install (1)
³⁄₈
" wall anchor with a minimum pull-out force of 1,000 lb per local codes at locations shown
2
B
Install (2) wall anchors per bracket with a minimum pull-out force of 100 lb per local codes at locations shown
2
C
Provide structural backing compliant with local building codes.
2
Structural Rough-Ins
(mm)
Areas highlighted in gray require sufficient backing
compliant with local building codes.
RIM
HEIGHT
VERTICAL HEIGHT
ADJUSTMENTS
FIXTURE
STYLE
NOTES
34"
No Adjustment
Standard ADA & TAS
At least one basin must meet dimensional
requirements and have proper reach, knee,
and toe clearance.
31"
*Subtract 3"
Juvenile ADA & TAS
At least one basin must meet dimensional
requirements and have proper reach, knee,
and toe clearance.
26"
*Subtract 8"
Junior
For use by younger children where ADA
guidelines are not a concern.
Secure bracket to wall using min. (2)
³⁄₈
"
anchor bolts to the left of C/L and min. (2)
³⁄₈
" anchor bolts to the right of C/L. The (2)
anchor bolts to the right of C/L must be
min. 16" apart from the anchor bolts to the
left of C/L. When mounting is complete,
check to ensure the bracket is level.
34"
(864)
31
¼
"
(794)
CL
B
A
A
B
Finished
Floor
36
½
" (927)
C
31
½
"
(801)
12"
(305)
23" (584)
5
⁵
/
₁₆
" (135)
5³/
₁₆
" (131)
16"
(407)
30
½
"
(775)
¾" (19)
Access Panel
Mounting Bracket