Metering Air Valve

The air valve timer is located next to the tube connector on the 
air valve body. The timer is capped with a filter to prevent dirt 
build-up on the timer. The air valve timing can be adjusted from 
5–60 seconds.

A

Remove filter cap and use a screwdriver to tighten or 
loosen the timer (see illustration at right). Turning the 
timer clockwise increases the time; turning the timer 
counterclockwise decreases the time.

B

Continue to adjust until the timer is set at desired 
length.

C

Replace filter cap over the timer.

Water Tube 

Connector

Air 

Valve

Filter 

Cap

Air Tube 

Connector

A

Push in the orange manual release button while 
pulling the tube out (see illustration at right) to 
disconnect the tube at the connector. No tools are 
needed.

B

To correct a leak, press tubing firmly into the 
connector and make sure it is seated.

C

If leak persists, remove tubing from the fitting, and 
trim the tubing end square with a razor-sharp knife. 
If leak continues, replace the fitting or contact your 
Bradley representative for assistance.

Manual 

Reset 

Button

Air Valve 

Tubing

Sealing 

Ring

Tube 

Stop

Gripping 

Ridge

Locking 

Slope

1

2

Adjust Air Valve Meter Time

Tube Connection Leaks

Tempered Line Adapter Option 

Part no. S39-804

(replaces S59-4000 if tempered line 
is used)

Strainer 

(173-028)