Bradford White AeroTherm Care And Cleaning Download Page 1

4

 

Bradford White heat pump Care and cleaning

.

If the water heater is to remain idle for an extended period of 

time, the power and water to the appliance should be turned 

off and the water heater drained to conserve energy and 

prevent a buildup of dangerous hydrogen gas. This unit has 

no power button, power can only be shut off at the circuit 

breaker or disconnect switch.
If the water heater has an anode depletion sensing feature 

(some models) and the water heater cannot be drained, it is 

recommended to leave the power turned on with the water 

heater in vacation mode to ensure that the feature will 

continue to operate properly while still conserving energy.

The water heater and piping should be drained if they might 

be subjected to freezing temperatures.
After a long shutdown period, the water heater’s operation 

and controls should be checked by qualified service 

personnel. Make certain the water heater is completely filled 

again before placing it in operation.

NOTE: Refer to the Hydrogen Gas Caution in the Operating 

Instructions (see page 3).

DRAINING THE WATER HEATER

CAUTION:

 Risk of Shock - 

Shut off power to 

the water heater before draining water.

DANGER:

 Risk of Scald - 

Before manually 

operating the relief valve, make certain no one will be exposed 

to the hot water released by the valve. The water drained from 

the tank may be hot enough to present a scald hazard and 

should be directed to a suitable drain to prevent injury or 

damage.

To drain the water heater, follow these steps:

1. Attach a garden hose to the drain valve located at the 

bottom of the unit and direct that hose to a drain. 

2. Turn off the cold water supply.

3. Admit air to the tank by opening a hot water faucet or 

lifting the handle on the relief valve

4. Open the drain valve with a flat screwdriver.
Note: See page 15 for product schematic.

EXTENDED SHUTDOWN PERIODS OR VACATIONS EXCEEDING VACATION MODE OPTIONS

Use a flat slot 

screwdriver to 

turn valve.

CLEARING THE CONDENSATION DRAIN TUBE

CLEANING THE FILTER

In the Hybrid, Heat Pump and High Demand/Boost modes, the heater 

moves air through the system and out the back of the unit. The filter 

is in place to protect the evaporator from dirt and dust. 
A clean air filter is important to get the highest efficiency. Occasion-

ally this filter will need to be cleaned (minimum once per year). When 

the filter requires cleaning, the Red light above the Filter button will be 

illuminated and an audible beep will sound. 

NOTE:

 If the filter gets too dirty, the unit will automatically switch to 

Electric/Standard mode and energy savings will be lost.
Leave the power on.  Remove the filter from  

the top of the unit. Squeeze two tabs and lift to remove the air filter. 

Once it has been removed, the filter can be vacuumed or wiped clean 

with a damp cloth or rinsed with warm water.
Once the filter has been cleaned and dried, it can be replaced by 

aligning it into the slots in the top of the unit and pushing it down into 

place. 

After the clean filter has been reinstalled, press and hold the 

FILTER

 

button.  If a heating cycle is on when the filter fault is reset, it will con-

tinue in electric mode to finish the cycle.  After that, it will automati-

cally revert to the mode it was in prior to being switched.

IMPORTANT:

 Filter must be cleaned when the alarm is displayed. A 

dirty filter will make the system work harder and result in a reduction 

of efficiency and possible damage to the system. In order to get the 

best energy efficiency available, make sure your filter is clean.

The main drain is intended to carry all condensate away.  If it is 

clogged, the heat pump will stop operating, the display will show 

F20, and an alarm will sound.  Press any button to silence the 

alarm, then clear the condensate drain by removing any drain 

lines and connections, and clearing debris. Reattach drain lines 

and connections, then allow the water heater to run.
Periodically inspect the drain lines and clear any debris that may 

have collected in the lines.

See Installation 

Instructions for 

more information.

Main drain line

Direct the 

main drain 

tube into a 

drain

Overflow

Filter

Tabs

Slots