background image

1

05.2008/24846000

YVL200 UK

1

1

2

3

2

GB

INSTRUCTIONS FOR USE
AND INSTALLATION 

BLACK/WHITE VIDEO ENTRY CONTROL YVL200

Monitor with video and secrecy of speech. With this 
monitor, the video signal may be transmitted by either 
a coaxial or a twisted pair.
Is equipped with the following controls (fig. 1):

 

Door release control (

1

)

 

Entry panel activation (

2

)

 

Centralized auxiliary control (stairs light and 
entry panel selection) (

1

)

 

Auxiliary control

  

Brightness 

  

Contrast

(

1

) The controls may only be activated by the monitor 

when it is switched on.
(

2

) The activation of the monitor and its subsequent con-

nection to the external entry panel, are only possible if the 
system is not engaged by other conversations.

WARNINGS FOR THE USER
- Please do not open or tamper the device (high 
voltage!).
- Please avoid knocking or bumping the appa-
ratus as it could result in the breakage of the 
picture tube and the consequent projection of 
glass fragments.
- In the case of breakdown or modification of 
the apparatus of the system (such as power sup-
plier...) please contact a specialized maintenance 
service.

Personal door-bell button

The monitor fits a landing call input with a two-tone 
call, fig. 11.

Connecting YPL unit

When the YPL unit is installed in the receiver, wire 
jumper BP1 must be cut (fig. 10).

 

YYP3 INTERCOM MONITOR WITH 
HANDSET

Used to manage up to 6 intercom units with 6 call 
buttons (two YP3).
The monitor permits to identify the source of a call: 
a continuous call tone identifies calls from other in-
tercom units and a two-tone call identifies calls from 
the external entry panel (or from the landing). A call 
from the entry panel during an internal conversation 
between two intercom units is indicated by the activa-
tion of the monitor and the emission of a low acoustic 
signal. In this case, communication with the entry 
panel 

(and hence the possibility of activating both 

the door release control and the stairs light relay)

 

may be established by hanging the handset of the 
intercom unit currently in use and lifting the handset 
of the one signalling a call.

SW1 switch

This switch (fig. 10), normally set to STD (standard 

BPT S.p.A.
Via Roma, 41
30020 Cinto Caomaggiore/VE/Italy
http: www.bpt.it/e-mail: [email protected] 

THESE INSTRUCTIONS SHOULD BE ATTACHED TO 
THE APPARATUS

mode), must be switched to INT when wanting to use 
the receiver as an intercom unit.

Entry panel selection in systems 
with several entrances

The VSI/200 selector allows you to select the external 
entry panel or camera from the monitor in sequential 
mode.  To operate the selector: press the 

entry panel 

activation button

  (

) to turn-on the monitor; and 

then press the 

auxiliary button

  (•) to select the entry 

panels.

NOTE. In the event a call is made from the entry panel, the 
selection in progress is interrupted. 
If the external call is addressed to the monitor making the 
selection, the monitor displays the image filmed at the 
external entry from where the call is addressed to another 
monitor, the image disappears from the monitor.

Function of each terminal (fig. 10)
Terminal block M1
3

 video 

signal 

coaxial

 

cable

 

4

 

video signal shield

I

f the video line ends at this monitor, connect a 75Ω (violet-

green-black-gold) resistor between terminals 3 and 4.

3 

pos. video signal

 

twisted pair

4 

neg. video signal

If the video line ends at this monitor, connect a 56Ω (green-
blue-black-gold) resistor between terminals 3-5 and 4-5.

5

 – 

14÷17,5 

V

6

 

+  supply voltage to monitor

7

 

call input from entry panel

8

 

audio to monitor

9

 

audio to entry panel

 10 

Aux - auxiliary services 

11 

24V 1A)

12 

call input from intercom receiver 

18 

stairs light 

19 

auto-switch on

20 

call input from landing

Terminal block M2 (accessories)

 connection 

for

 YAL 

loudspeaker

7A  connection for YPL module

Function of connector
CN1 to connect to monitor YV.

Technical features

•  Supply voltage: 14÷17,5 VDC.
•  Current demand: max. 508 mA (<10 mA quiescent).
•  Bandwidth response at -3dB: 5MHz.
•  Video input: 1Vpp from coaxial line; + video signal 

0,6Vpp, - video signal 0,6Vpp from differential line 
(twisted pair).

•  Video input impedance: ≥22kΩ
• Call signal: two-tone call signal from the entry panel or 

from the landing.  

•  Audio secrecy to entry panel.
 •  CCIR (EIA) standard.
•  Picture screen: 4” (10 cm).
•  Horizontal frequency: 15,625 Hz (15,750 Hz EIA).
•  Vertical frequency: 50 Hz (60 Hz EIA).
•  Working temperature range: from 0 °C to +35 °C.
• Dimensions: 205x215x63mm.

The monitor is protected by the slow blow fuse F1 - T 
630mA - located on monitor’s printed card, fig.10.

INSTALLATION

WARNING. It is recommended to install the monitor 
in a dry place.

Open the video entry control as shown in figures 2 
and 3. Remove the connector (fig. 4) and install the 
video entry control as shown in figures 5, 6.
For even more secure fastening, remove the receiver 
support with a screwdriver through the slot (fig. 7) and 
fasten the video entry control as shown in figure 8.
Connect (fig. 4) an re-install the video entry control as 
shown in figure 9.

DISPOSAL

Do not litter the environment with packing material: 

Reviews: