Effectivity: 912 i Series
Edition 1/Rev. 0
d0
535
5.
fm
MAINTENANCE MANUAL
BRP-Powertrain
76-70-00
Page 26
July 01/2012
TEMPERATURE SENSOR (OTS) - INSTAL-
LATION
Fig. 29
Fig. 30
TEMPERATURE SENSOR (EGT1/EGT2/
EGT3/EGT4) INSTALLATION
Fig. 31
Step
Procedure
1
Clean the thread of the temperature sen-
sor.
2
Lubricate the thread of the pressure sen-
sor with LOCTITE 243 and use an SW 19
open-ended spanner part no. 876130 (or
a similar tool) to tighten it.
Tightening torque 15 Nm (88.48 in. lb.).
3
Plug the respective wiring harness con-
nector into the corresponding tempera-
ture sensor. See section 76-50-00.
1. Temperature sensor (OTS)
Step
Procedure
4
Attach cable ties.
1. Temperature sensor (OTS)
2. Cable ties
Step
Procedure
1
Clean the thread of the temperature sen-
sor.
2
Lubricate thread of temperature sensor
with LOCTITE ANTI SEIZE.
1. Temperature sensor
2. Inlet pipe
Summary of Contents for Rotax 912 i Series