Effectivity: 912 i Series
Edition 1/Rev. 0
d
053
55.
fm
MAINTENANCE MANUAL
BRP-Powertrain
76-70-00
Page 25
July 01/2012
PRESSURE/TEMPERATURE SENSOR
(AAPTS) - INSTALLATION
TEMPERATURE SENSOR (CTS) - INSTAL-
LATION
Fig. 26
TEMPERATURE SENSOR (MATS) - INS-
TALLATION
Fig. 27
Fig. 28
Step
Procedure
1
Follow the aircraft manufacturer's instruc-
tions for assembly.
2
Plug the respective wiring harness con-
nector into the corresponding pressure or
temperature sensor.
See section 76-50-00.
Step
Procedure
1
Clean the thread of the temperature sen-
sor.
2
Lubricate the thread of the pressure sen-
sor with LOCTITE 243 and use an SW 19
open-ended spanner part no. 876130 (or
a similar tool) to tighten it.
Tightening torque 15 Nm (88.48 in. lb.).
3
Plug the respective wiring harness con-
nector into the corresponding tempera-
ture sensor. See section 76-50-00.
1. Temperature sensor (CTS)
Step
Procedure
1
Clean the thread of the temperature sen-
sor.
2
Fasten the temperature sensor and seal-
ing ring with an SW 19 open-ended span-
ner part no. 876130 (or similar tool).
Tightening torque 15 Nm (88.48 in. lb.).
1. Temperature sensor (MATS)
2. Sealing ring
Step
Procedure
3
Plug the respective wiring harness con-
nector into the corresponding tempera-
ture sensor. See section 76-50-00.
4
Attach cable ties (strain relief).
1. Temperature sensor (MATS)
2. Cable ties